background image

If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones,
safety areas), compliance with all applicable regulations and standards must be ensured.

Once the drive has been installed, the fitter must mark the used tubular drive in the “Technical data”
chapter and make a note of the installation position.

Caution

Safety instructions for avoiding serious injuries.

When electrical or electronic equipment and units are operated, certain components,
e.g., the power supply unit, are live. Physical injuries or damage to property can result in
the event of unauthorised interventions or failure to heed warnings.

Be careful when touching the tubular drive, as it heats up during operation for technical
reasons.

Before installation, shut down all lines and control devices that are not essential for op-
eration.

Crushing or shearing points must be avoided or protected.

When installing the drive, all-pole disconnection from the mains with a contact gap of at
least 3 mm per pole must be provided (EN 60335).

If the mains connecting cable is damaged, it may only be replaced by the manufacturer.
If the drive has a plug-in connecting cable, it must be replaced with the same type of
mains connecting cable, which is available from the drive manufacturer.

Attention

Safety instructions for avoiding property damage.

Ensure that there is adequate clearance between moving parts and adjacent objects.

The drive must not be carried by the mains connecting cable.

All latching connections and fastening screws on the brackets must be checked to en-

sure that they are secure.

Ensure that nothing rubs against the tubular drive, such as shading solution attach-

ments, screws, etc.

The drive must be fitted horizontally.

Intended use

The type of tubular drive described in these instructions is intended solely for the operation of roller shutters.
This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti-lifting devices (e.g.,
Zurfluh-Feller, Simu, GAH Alberts and Deprat). These are detected automatically.
For sun protection applications, please use only the types of tubular drive designed for this purpose.
This type of tubular drive is designed for use in single systems (one drive per barrel).
The tubular drive must not be used in potentially explosive areas.
The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube.
Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac-
tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not
accept liability for damages or injury arising from such actions.
Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac-
cept liability for damage or injury resulting from improper usage.

Attention

Only use anti-lifting devices if the roller shutter laths are sufficiently strong. The closed

curtain must not project beyond the guide tracks or else there is a risk of the joint between

the top two laths being subjected to excessive strain and getting damaged.

5 - en

Summary of Contents for E02

Page 1: ...s for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 990 0a 20 05 2022 ...

Page 2: ...6 Setting the limit positions using the programming unit 9 Deleting the limit positions using the programming unit 10 Deleting the limit positions with a rotary switch or a locking button 10 Obstruction detection Blockage detection 11 Information for the electrician 11 Disposal 11 Maintenance 11 Technical data dia 45 12 What to do if 12 Sample wiring diagrams 13 Declaration of conformity 14 2 en ...

Page 3: ... setting up the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates measure...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ...stening screws on the brackets must be checked to en sure that they are secure Ensure that nothing rubs against the tubular drive such as shading solution attach ments screws etc The drive must be fitted horizontally Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters This type of tubular drive supports not only curtain att...

Page 6: ...you can pull out the connecting cable along with the flat head screwdriver A locating latch Assembly Assembling the drive Attention To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used Prior to mounting the fitter must ensure that the masonry and the system being motorised are sufficiently robus...

Page 7: ...r Fitting the ring onto the thrust ring Assembling the drive adapter with safety catch on the drive shaft Disassembling the drive adapter with safety catch on the drive shaft Assembling and disassembling the drive adapter with drive adapter safety catch or screw connection Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive...

Page 8: ...apter are secure in the tube Mount the assembled unit comprising shaft tubular drive and idler on the box and secure the drive with a splint or spring pin according to the type of wall bracket fixing Automatic setting of limit positions is possible where a stop system is present on both sides using the rotary switch set Item no 4901 001 158 0 a standard rotary switch or the programming unit for dr...

Page 9: ...n has been set in that direction of movement The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing a short way and removing the obstruc tion The desired limit position can be set by opening clos...

Page 10: ...on Travel button Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the programming button again The tubular drive acknowledges Both limit positions are deleted Deleting the limit positions with a rotary switch or a locking button The switching commands s...

Page 11: ...ctor L1 to control the up and down direction Other devices or consumers lamps relays etc must not be dir ectly connected to the drive connecting cables For this purpose the drives and additional devices must be decoupled by relay controls When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided Attention Only use mechanically or ...

Page 12: ...xternal devices reset limit positions Stops have broken off or one or several attachments are broken Repair system reset tubular drive then re program limit positions Tubular drive stops arbitrarily cannot be restarted in the same direction Use a more powerful tubular drive Ensure that the system runs smoothly Delete limit positions then re program limit positions Tubular drive does not run in the...

Page 13: ...o the left Controlling one several drive s via a single switch button Electronic black brown blue green yellow Electronic Central group and individual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 13 en ...

Page 14: ...Declaration of conformity 14 en ...

Page 15: ...15 ...