background image

Setting the limit positions using the programming unit

Programming button

Travel button

Programming unit for drives with electronic limit switching.

Attention

The programming unit is only designed for the commissioning, not for continuous opera-

tion.

Intelligent installation management

Completion of installation following automatic setting of limit position "Stop"

Next time the “stop” limit position is travelled to, this position will be provisionally saved as the limit position. Once the limit position
has been detected at this position 3 times in a row without any problems, it will be definitively saved. This normally takes place dur-
ing regular operation.
To complete installation quickly, it is sufficient to travel to the “stop” limit position 3 times in a row from approx. 20 cm.

Limit position status indicator

A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.

If the tubular drive switches off prematurely while opening or closing, due to an obstruc-

tion, the obstruction can be cleared by reversing a short way and removing the obstruc-

tion. The desired limit position can be set by opening/closing again.

When first installing using springs and adjusting the limit position "...to lower stop", the

barrel in the lower limit position turns approx. 1/4 of a turn further than usual. In doing so,

the tubular drive is able to automatically detect the use of anti-lifting devices or springs.

The tubular drive switches off automatically.

Upper stop to lower stop

Open to the permanent upper stop.

The tubular drive switches off automatically.

Then close to the permanent lower stop without pausing. During travel, the end posi-
tion status indicator (ESI) must be displayed before the end position is reached.

The tubular drive switches off automatically.

The limit positions are now set.

9 - en

Summary of Contents for E02

Page 1: ...s for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 990 0a 20 05 2022 ...

Page 2: ...6 Setting the limit positions using the programming unit 9 Deleting the limit positions using the programming unit 10 Deleting the limit positions with a rotary switch or a locking button 10 Obstruction detection Blockage detection 11 Information for the electrician 11 Disposal 11 Maintenance 11 Technical data dia 45 12 What to do if 12 Sample wiring diagrams 13 Declaration of conformity 14 2 en ...

Page 3: ... setting up the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates measure...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ...stening screws on the brackets must be checked to en sure that they are secure Ensure that nothing rubs against the tubular drive such as shading solution attach ments screws etc The drive must be fitted horizontally Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters This type of tubular drive supports not only curtain att...

Page 6: ...you can pull out the connecting cable along with the flat head screwdriver A locating latch Assembly Assembling the drive Attention To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used Prior to mounting the fitter must ensure that the masonry and the system being motorised are sufficiently robus...

Page 7: ...r Fitting the ring onto the thrust ring Assembling the drive adapter with safety catch on the drive shaft Disassembling the drive adapter with safety catch on the drive shaft Assembling and disassembling the drive adapter with drive adapter safety catch or screw connection Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive...

Page 8: ...apter are secure in the tube Mount the assembled unit comprising shaft tubular drive and idler on the box and secure the drive with a splint or spring pin according to the type of wall bracket fixing Automatic setting of limit positions is possible where a stop system is present on both sides using the rotary switch set Item no 4901 001 158 0 a standard rotary switch or the programming unit for dr...

Page 9: ...n has been set in that direction of movement The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing a short way and removing the obstruc tion The desired limit position can be set by opening clos...

Page 10: ...on Travel button Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the programming button again The tubular drive acknowledges Both limit positions are deleted Deleting the limit positions with a rotary switch or a locking button The switching commands s...

Page 11: ...ctor L1 to control the up and down direction Other devices or consumers lamps relays etc must not be dir ectly connected to the drive connecting cables For this purpose the drives and additional devices must be decoupled by relay controls When installing the drive all pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided Attention Only use mechanically or ...

Page 12: ...xternal devices reset limit positions Stops have broken off or one or several attachments are broken Repair system reset tubular drive then re program limit positions Tubular drive stops arbitrarily cannot be restarted in the same direction Use a more powerful tubular drive Ensure that the system runs smoothly Delete limit positions then re program limit positions Tubular drive does not run in the...

Page 13: ...o the left Controlling one several drive s via a single switch button Electronic black brown blue green yellow Electronic Central group and individual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 13 en ...

Page 14: ...Declaration of conformity 14 en ...

Page 15: ...15 ...

Page 16: ......

Reviews: