background image

Sample wiring diagrams

The assignment of the black and brown wires according to the direction of travel is de-

pendant on how the drive is installed (mounted to the right or to the left).

Controlling one/several drive(s) via a single switch/button

Ele

ctr

oni

c

bla

ck

br

ow

n

blu

e

g

reen-yell

o

w

Electr

oni

c

Central, group and individual control using Centronic UnitControl UC42

Mains 230 V / 50 Hz

Central

Group

Individual

Individual

230 V / 50 Hz

Central cable

(connection to further control units)

230 V / 50 Hz

230 V / 50 Hz

E

le

c

tr

o

n

ic

s

230 V / 50 Hz

Control unit

17 - en

Summary of Contents for E03

Page 1: ...s for roller shutters Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 546 0c 19 05 2022 ...

Page 2: ... limit positions using the programming unit 11 Adjusting the limit positions with a rotary switch or a locking button 12 Deleting the limit positions with a rotary switch or a locking button 14 Obstruction detection Blockage detection 14 Additional upper anti freeze mechanism 14 Information for the electrician 15 Disposal 15 Maintenance 15 Technical data dia 35 15 Technical data dia 45 16 What to ...

Page 3: ... setting up the equipment The date of manufacture comes from the first four digits of the serial number The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week Example 34th calendar week in 2020 Ser No 2034XXXXX Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates measure...

Page 4: ...y the drive manufacturer If any questions or uncertainties regarding the safety instructions contained in the standard arise please contact the manufacturer of the part or end product in question All applicable standards and regulations for electrical installation must be complied with All work including maintenance and cleaning on electrical installations as well as other system parts must always...

Page 5: ... they are secure Ensure that nothing rubs against the tubular drive such as shading solution attach ments screws etc The drive must be fitted horizontally Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti lifting d...

Page 6: ...you can pull out the connecting cable along with the flat head screwdriver A locating latch Assembly Assembling the drive Attention To connect the drive to the driven part solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used Prior to mounting the fitter must ensure that the masonry and the system being motorised are sufficiently robus...

Page 7: ...r Fitting the ring onto the thrust ring Assembling the drive adapter with safety catch on the drive shaft Disassembling the drive adapter with safety catch on the drive shaft Assembling and disassembling the drive adapter with drive adapter safety catch or screw connection Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive...

Page 8: ...apter are secure in the tube Mount the assembled unit comprising shaft tubular drive and idler on the box and secure the drive with a splint or spring pin according to the type of wall bracket fixing Automatic setting of limit positions is possible where a stop system is present on both sides using the rotary switch set Item no 4901 001 158 0 a standard rotary switch or the programming unit for dr...

Page 9: ...imit positions Upper stop to lower stop Upper point to lower point Upper stop to lower point Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing a short way and remov...

Page 10: ...o the permanent upper stop The tubular drive switches off automatically Then close to the desired lower limit position Press the programming button of the programming unit for 3 seconds The tubular drive acknowledges The limit positions are now set Upper point to lower stop Open to the desired upper limit position Press the programming button of the programming unit for 3 seconds The tubular drive...

Page 11: ... Also leave a pause of 1 sec between the individual steps of the deletion sequence black brown blue green yellow black brown blue green yellow Programming button Travel button Press the programming button and keep it pressed Then press down the travel button and keep it pressed Now release the programming button but continue to keep the travel button pressed Next press the programming button again...

Page 12: ...int Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times If the tubular drive switches off prematurely while opening or closing due to an obstruc tion the obstruction can be cleared by reversing a short way and removing the obstruc tion The desired limit position can be set by opening closing again When ...

Page 13: ... Open to the permanent upper stop The tubular drive switches off automatically Then close to the desired lower limit position Carry out the following sequence without interruption between the individual drive commands The tubular drive acknowledges until STOP and hold until The limit positions are now set Upper point to lower stop Open to the desired upper limit position Carry out the sequence bet...

Page 14: ...strip on the window sill To avoid overly sudden deactivation during closing the drive only responds to an obstruction one or two revolutions after the im pact Additional upper anti freeze mechanism The upper anti freeze mechanism helps to prevent the roller shutter from freezing in the upper limit position as the roller shutter stops just before the upper stop The distance from the upper stop is a...

Page 15: ...or switching the running direction must be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from damp Once you have finished wiring everything to the control ALWAYS check the right direction assignment of the drive to the control buttons UP and DOWN EXTEND and RETRACT If the drive is to be operated with devices which conta...

Page 16: ...move external devices delete limit positions and then reset limit positions Tubular drive stops arbitrarily cannot be restarted in the same direction Tubular drive has detected an increase in load Briefly run the curtain in the opposite direction then continue in the desired direction Tubular drive is overloaded Use a higher torque tubular drive Delete limit positions then reprogram limit position...

Page 17: ...o the left Controlling one several drive s via a single switch button Electronic black brown blue green yellow Electronic Central group and individual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 17 en ...

Page 18: ...Declaration of conformity 18 en ...

Page 19: ...19 ...

Page 20: ......