Deleting the limit positions using the programming unit
Connect the wires of the tubular drive to those of the same colour in the programming unit
and switch on the power supply.
Please pause for 1 sec after the last drive command before beginning the deletion se-
quence. Also leave a pause of 1 sec between the individual steps of the deletion sequence.
black
brown
blue
green-yellow
black
brown
blue
green-yellow
Programming button
Travel button
Press the programming button and keep it pressed.
Then press down the travel button and keep it pressed.
Now release the programming button, but continue to keep the travel button pressed.
Next press the programming button again.
▻
The tubular drive acknowledges.
►
Both limit positions are deleted.
12 - en
Summary of Contents for E22
Page 25: ...Declaration of conformity 25 en ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ......