6.5.3. De-Activation (Switching OFF)
Push the slide button to OFF position, the PLB will stop immediately.
Carefully check the PLB indicators, that the LED is not flashing and that the Buzzer is not beeping.
After the first activation the control button will be as follows:
MR109: OFF position after ACTIVATION.
This indicates that the beacon has been activated once.
In this state the master power switch disconnects the battery from the beacon circuitry.
6.5.4. Beacon Storage
Be sure that the slide button is in the OFF position and that the antenna is correctly bent into the
cover.
Avoid storage at temperatures above 25°C to keep the self discharge ratio at 2% year, the ideal tem-
perature range is from -30°C to +25°C. (The lower the temperature, the lower the self discharge ratio
will be). For example, at 40°C the battery self discharge will be around 9% per year, and at 60°C this
ratio is around 18%.
Do not keep the PLB in any car exposed to direct sunlight, the car temperature could reach over 70°C
and the battery may be damaged.
During long storage periods you should test the PLB once every 3 months.