7. SPECIFICATION
7.1.
Approvals and Standards
Approvals
:
Cospas-Sarsat T.007 Class 2
Standards and Regulations
:
RTCM 76-2002/SC110-STD
RTCM
23-2003/SC110-274
ETSI EN 302 152-1 V1.1.1 2003-11
EN
60945:2002
7.2. Battery
Type
: Non
Re-Chargeable
LiMnO2,
Nominal operating voltage
:
9 VDC ……. 6,5 VDC,
Nominal battery capacity
:
4.5 Ah
Battery shelf life
:
5 years (from cell’s date of manufacture)
7.3.
Storage temperature range
Class 2 PLB
:
- 30°C to + 70°C
(recommended: -30°C to +25°C)
7.4.
Operating temperature range
Class 2 PLB
:
- 20°C to + 55°C
7.5. Minimum
Operating
time
Class 2 PLB
:
≥
24 h at -20°C
7.6. Transmitter
406
MHz
Operating frequency
:
406.028 MHz
Frequency accuracy
:
≤
± 1000 Hz
Frequency stability
:
≤
± 1.0 * 10
-9
; medium term stability
≤
± 2.0 * 10
-9
; short term stability
≤
± 3.0 * 10
-9
; residual freq. Stability
+2 / -5 KHz over 5 years; long term stability (ageing).
RF output power
:
5 W;
±
2 dB
Data
encoding
: Bi-Phase
L
Modulation
: Q0X:
DP
=
±
1 rad
Transmission time
:
Short Message: 440 ms
: Long
message:
520
ms