28
BECKER VADS 1500+
4.7 TECHNICALDATA
The general technical data of the VADS 1500+ are listed in table form below:
Vacuum pump
VADS 1500+
Compressor
VADS 1500+
Pumping speed
750 - 1380 m³/h
Delivery quantity
750 - 1230 m³/h
Operating vacuum (continuous
operation)
200 mbar abs.
Operating pressure (continuous
operation)
2 bar abs. (1 bar rel.)
Installed inverter/motor power
30/37 kW
Installed inverter/motor power
45/37 kW
Compressor speed
6600-12000 min-1
Compressor speed
4800-10000 min-1
Sound level
at typical operating pressure
1)
75 dB(A) - (110 Hz)
450 mbar abs.
Sound level
at typical operating pressure
1)
85 dB(A) - (110 Hz)
650 mbar rel.
Length
1600 mm
Length
1600 mm
Wide
1510 mm
Wide
1510 mm
Height
1806 mm
Height
1806 mm
Weight
ca. 1200 kg
Weight
ca. 1200 kg
Suction connection
DN 150 / PN 6
Suction or intake connection
DN 150 / PN 6
Exhaust air connection
DN 150 / PN 6
Compressed air connection
DN 150 / PN 6
1)
Sound level according to EN ISO 2151:
90 dB(A) at 200 Hz and free intake
1)
Sound level according to EN ISO 2151:
88 dB(A) at 165 Hz and 800 mbar rel. humidity
Table 4.2: General technical data
4.8 FUELS AND CHEMICALS
CAUTION
Contamination and damage to the environment by operating materials
The operating materials used for the proper functioning of the VADS 1500+ and water contaminated with these
operating materials can pose a danger to the environment.
Suitable absorbents must always be kept on hand to ensure rapid absorption of spills and contaminated water.
Used absorbents must always be disposed of according to the prescribed procedures.
All environmental protection regulations must always be observed when handling and disposing of operating
materials.
Operating materials and contaminated water must be disposed of in accordance with the environmental pro-
tection conditions applicable on site.
DANGER
Risk of infection and poisoning from eating and drinking in the machine area
Eating and drinking is prohibited in the entire machine area.