BECKER VADS 1500+
33
Connection of a USB stick.
Status of the safety valve.
Status of the weekly timer, if configured.
Status of the machine in text form.
Display of the currently logged in user, as well as the countdown timer for automatically
logging out the user.
The different display pages are selected using the buttons on the right and left of the edge.
Main page:
An overview of the machine‘s operating status and the various system parameters is displayed here.
In manual mode, the unit can be operated by specifying the speed in the input field.
The screw stage rotates with the frequency entered there. Inadmissible setpoint specifications
are not possible.
The main page displays the actual frequency from the frequency inverter, the operating hours of the unit, the instanta-
neous power, the actual pressure and the specified setpoint.
Maintenance:
The operating hours, the number of starts and the maintenance information are displayed here. With extended rights,
maintenance can also be confirmed or postponed here.
Messages:
The current faults, warnings or extended information are displayed here and can be acknowledged.
Protocol:
Faults, warnings or extended information from the past are displayed here and can be deleted.