Operating Instructions WSTE 500 and WSTE 1000
20
E
N
G
L
I
S
H
Functions and connections
WSTE 500
WSTE 1000
Internal Functions:
Reversing control ...............................................................................
X
X
Sensor for bottom pneumatic or electrical safety edge ..................
X
X
Fault display .......................................................................................
X
X
Safety stop display ............................................................................
X
X
Reclosing display ...............................................................................
X
Display for special functions 1 ..........................................................
X
X
Display for special functions 2 ..........................................................
X
Cycle counter .....................................................................................
X
X
UP, STOP and DOWN function keys
(integrated into housing cover) .........................................................
X
X
Keyswitch for activation of partial opening .......................................
X
Operating voltage 3 x 400 V (or 3 x 230 V to order) ........................
X
X
Operating voltage 1 x 230 V ..............................................................
X
X
Extra-low voltage output 24V / 100mA
(e.g. for light barrier) ..........................................................................
X
X
Connections for:
External emergency stop switch, wicket door and spring
fracture protection ..............................................................................
X
X
Slack cable limit switch .....................................................................
X
X
Emergency stop switch .....................................................................
X
X
Additional 3-way push-button:
(Function: UP, STOP, DOWN inside) ................................................
X
X
UP button input (Function: UP outside) ...........................................
X
DOOR - STOP during opening, e.g. roll-up anti-trap safety device
X
DOOR - STOP during closing, e.g. light barrier ...............................
X
X
Automatic reclosing ...........................................................................
X
X
UP / STOP / DOWN step sequence switch:
DOOR - inside (e.g. ceiling pull switch) ............................................
X
X
DOOR - outside (e.g. keyswitch) ......................................................
X
Simple traffic light ..............................................................................
X
Two-way traffic light ...........................................................................
X
Potential-free contact for special functions 1 ...................................
X
Potential-free contact for special functions 2 ...................................
X
Can be supplied with:
Remote control (can also be retrofitted) ...........................................
X
X
EMERGENCY STOP switch in housing cover
(can also be retrofitted) .....................................................................
X
X
EMERGENCY STOP switch lockable (can also be retrofitted) ........
X
X
Connection for sensor slipping clutch ..............................................
X
X
The WSTE 500 / WSTE 1000 door controls are electronic reversing controls. They are designed for use with door
drives with a mechanical limit stop. These drives operate with 6 limit switches and, in conjunction with WSTE 500 /
WSTE 1000 controls, are designed for operating sectional and roller doors.