background image

Instruction Manual

 – Model AFG Oil Burner

12

U.S.A.: P. O. Box 1289 

 Elyria, Ohio 44036

Canada: R. W. Beckett Canada, Ltd. 

 Unit #3, 430 Laird Road 

 Guelph, Ontario, N1G 3X7

This burner must be installed, adjusted and started only by a 

quali-

fied service agency 

— an individual or agency, licensed and experienced

with all codes and ordinances, who is responsible for the installation and adjust-
ment of the equipment.

Have your equipment 

inspected and adjusted at least annually

 by

your 

qualified service agency 

to assure continued proper operation.

Installation and adjustment of the burner requires technical knowledge and
the use of combustion test instruments. 

Do not tamper

 with the unit or

controls. Call your 

qualified service agency

.

Incorrect operation of the burner could result in severe per-
sonal injury, death or substantial property damage.

The following could result in fire hazard, severe personal injury, death or sub-
stantial property damage. Read carefully.

Never 

attempt to 

use gasoline

 

in your heating appliance.

Never store gasoline

 

or 

combustible materials

 

near the burner or

appliance.

Never 

attempt to burn 

garbage or refuse

 

in your appliance.

Never 

attempt to 

light the burner/appliance

 

by throwing burning ma-

terial into the appliance.

Never 

attempt to use 

crankcase or waste oil

 

or material other than the

approved fuel oils in this burner.

Never 

restrict the air inlet openings to the burner or the combustion air

ventilation openings in the room.

Printed in U.S.A.         © 2001 R. W. Beckett Corporation

Owner service and maintenance

Properly installed and maintained, your 

AFG 

burner will provide years of effi-

cient, trouble-free operation. Please take care of your equipment by following the
warnings provided and by doing the following (notify your qualified service agency
if you find anything wrong):

Annually (minimum)

Have your burner/heating appliance serviced at least annually by your quali-
fied service agency as noted above.

Daily

Check the room in which your burner/appliance is installed. Make sure:

•  air ventilation openings are clean and unobstructed

•  nothing is blocking the burner inlet air openings

•  no combustible materials are stored near the heating appliance

•  there are no signs of oil or water leakage around the burner or appliance.

Weekly

Check your oil tank level. Always keep your oil tank full, especially during the
summer, in order to prevent condensation of moisture on the inside surface
of the tank.

Owner’s information

Service & maintain burner

Form Number 6104BAFG R1001

Beckett warrants its equipment specifically to those who have purchased it for
resale, including your qualified service agency (dealer). In the event of any prob-
lems with your equipment or its installation, you should contact your dealer for
assistance.

Warranty

The OilHeat Manufacturers' Association supports the use of low sulfur fuels as defined by ASTM D396, Grades Number 1 Low Sulfur and Number 2 Low
Sulfur, as the preferred heating fuel for the following reasons:

Low sulfur fuels reduce deposits on heat exchanger surfaces, extending the service interval between cleanings.

The reduced deposits increase the efficiency of the appliance.

Low sulfur fuels reduce particulate emissions.

Low sulfur fuels reduce oxides of nitrogen emissions.

Summary of Contents for 120 Vac/60 Hz

Page 1: ...Types F M air tubes Motor voltage 120 Vac 60 Hz MODEL Oil Burner Instruction Manual AFG AFG AFG burner with type F air tube Type M air tube combinations Type L1 head Type V1 head...

Page 2: ...Prepare burner 5 Check adjust Z dimension 6 Set head position adjusting plate V1 head only 7 Adjust pipe wire burner Mount burner on appliance 8 Connect fuel lines 8 Wire burner 8 Startup adjust burn...

Page 3: ...notify the carrier at once and file the appropriate claim When contacting Beckett for service information Please record the burner serial number and have available when calling or writing You will fin...

Page 4: ...f the equipment room developing negative pressure because of exhaust fans or clothes dryers for example either pipe combustion air directly to the burner or provide a sealed enclosure for the burner a...

Page 5: ...the appliance manufacturer s instructions or the Beckett OEM Specification Guide part number 6711 Do not omit the LFRB when specified Omitting the baffle when specified or installing the baffle when...

Page 6: ...e nozzle line See Figure 2 Loosen the splined nut from the nozzle line Loosen the hex head screw securing the escutcheon plate to the burner housing Place the end of a ruler at the face of the nozzle...

Page 7: ...be installed Even if factory set verify that the Z dimension has not been changed 2 Use the following procedure to adjust the Z dimension if it is not correct Turn off power to the burner Disconnect t...

Page 8: ...ut the bypass plug installed You must install this plug on two pipe oil systems DO NOT install the plug in the fuel unit if connected to a one pipe oil system Failure to comply could cause fuel unit s...

Page 9: ...4G or equivalent primary control Figure 7 Typical wiring R7184 primary control R7184P shown Adjust pipe wire burner Electrical shock hazard Disconnect power before servicing Electrical shock hazard Di...

Page 10: ...ial If motor is not permanently lubricated oil motor with a few drops of SAE 20 nondetergent oil at each oil hole DO NOT over oil motor Excessive oiling can cause motor failure Check motor current The...

Page 11: ...Instruction Manual Model AFG Oil Burner 11 Replacement parts Awaiting new info Service maintain burner...

Page 12: ...d maintenance Properly installed and maintained your AFG burner will provide years of effi cient trouble free operation Please take care of your equipment by following the warnings provided and by doi...

Reviews: