Commissioning
106
───
Version: 4.3
AM8000 and AM8500
10.3
Prerequisites during op-
eration
Pay attention to the following points during operation:
• Pay attention to atypical noise development
• Pay attention to smoke development
• Always check drive surfaces and cables for dirt, leaks, moisture
or dust
• Check temperature development
• Check for lubricant leakage
• Observe recommended maintenance intervals
• Check function of safety devices
For motors with fan cover [+]:
• Check air intakes for contamination
• Check that the motor and fan cover [+] are firmly seated
• Observe tightening torques
10.4
After operation
WARNING
Place the machine or plant in a safe state
Make sure that the rotor comes to a complete stop.
When the holding brake [+] is released, the rotor moves without
remanent torque. Rotating components can lead to serious in-
juries.
Summary of Contents for AM8000 Series
Page 1: ...Operation Instructions EN AM8000 and AM8500 Synchronous Servomotors 8 27 2020 Version 4 3 ...
Page 2: ......
Page 122: ......