Product overview
C6030
12
Version: 2.7
3.2.3
USB
The Industrial PC has four USB 3.0 interfaces (X106-X109). They are used to connect peripheral devices
with USB interfaces.
Each of the four USB interfaces supplies up to 900 mA current and is electronically fused. USB ports A & B
and C & D are feature common overcurrent protection (overcurrent detection). If an overcurrent occurs at
one of the ports, the two jointly protected USB ports are switched off.
1
2
3
4
4
3
2
1
4
3
2
1
4
3
2
1
X106
X107
X108
X109
USB A
USB B
USB C
USB D
5
6
7
8
9
5
6
7
8
9
5
6
7
8
9
5
6
7
8
9
Fig. 4: C6030_USB interface pin numbering
Table 5: USB interface pin assignment
Pin
Assignment
Shield
GND
1
Vbus
2
D -
3
D +
4
GND
5
StdA_SSRX -
6
Std
7
GND_DRAIN
8
StdA_SSTX -
9
Std