background image

 

Operating Instructions 

 

Operating Instructions 

 

Switching the Industrial PC on and off 

Switch on 

The Industrial PC does not have its own mains switch. The Industrial PC 
will start when the equipment is switched on, or when it is connected to the 
power supply. 
 

Shutting down and 
switching off 

When the plant is switched off, or when it is disconnected from its power 
supply, the Industrial PC will be switched off. 
 
Control software such as is typically used on Industrial PCs permits various 
users to be given different rights. A user who may not close software may 
also not switch the Industrial PC off, since data can be lost from the hard 
disk by switching off while software is running. 
 
 

 

Warning

 

First shut down, then switch off the PC! 

If the Industrial PC is switched off as the software is writing a file to the 
hard disk, the file will be destroyed. Control software typically writes 
something to the hard disk every few seconds, so that the probability of 
causing damage by switching off while the software is running is very high. 
 

 

Warning

 

When you have shut down the Industrial PC, you have to switch off power 
supply for at least 10 seconds before rebooting the system. 
After resetting power supply the PC will start booting automatically. 
 

Reset key 

A Reset button (

1

) for rebooting the system is 

provided behind the side door for the drives. 

LEDs 

Three LEDs are located next to the Reset button (

2

). 

The red LED signalizes hard disk activity, the green LED signalizes the 
presence of the voltage supply, while the yellow LED indicates Turbo 
operation. 

1

2

 

 

First switching on and driver installation 

 

When you switch on the Industrial PC for the first time, the pre-installed 
operating system (optional) will be started. In this case, all the required 
drivers for any additional, optional hardware components ordered with the 
PC will already have been installed. 
 
If the PC was ordered without operating system, you have to install the 
operating system and the driver software for any auxiliary hardware 
yourself. Please follow the instructions in the documentation for the 
operating system and the additional devices. 

 CP71xx 

15 

Summary of Contents for CP71 Series

Page 1: ...Installation and Operating instructions for Panel PC CP71xx Version 1 2 Date 2006 03 06...

Page 2: ......

Page 3: ...of the PC 10 Earthing measures 10 Power Supply Connection 11 Electrical data 11 Pin assignment of the connector 11 Fitting the cable 12 Assembling the connector 12 Connecting Power Supply 13 Cable Cro...

Page 4: ...Table of contents 6 7 Assembly dimensions 20 Appendix 21 Technical data 21 Approvals 21 FCC Federal Communications Commission Radio Frequency Interference Statement 21 FCC Canadian Notice 21 2 CP71xx...

Page 5: ...et out in 443 of the German Civil Code or a statement about the assumed use according to the contract as set out in 434 para 1 clause 1 no 1 of the German Civil Code In the event that it contains tech...

Page 6: ...he equipment must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have be...

Page 7: ...ional regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines...

Page 8: ...wo M4 screws 1 using a combination wrench SW 7 and the Allen screw 2 using a No 2 Allen key see photo above The cover of the housing can then be removed to the rear i Note The position of the screws v...

Page 9: ...shead screw a and removing the sheet metal cover you can pull out the CD ROM drive Unscrewing the crosshead screw b and removing the card holder allows access to the free slot b 3 4 a 5 2 6 1 Access t...

Page 10: ...interface COM1 4 which is connected to a 9 pin SUB D pin connector DVI I interface in use DVI The DVI I interface 5 is used for connecting the Control Panel USB interface in use USB3 An additional US...

Page 11: ...n temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a de...

Page 12: ...far as possible Use the position of the screen as a guide for the correct installation height it should be optimally visible for the user at all times The PC should not be exposed to direct sunlight W...

Page 13: ...rent carrying capacity of the 24 V power supply unit Output voltages from the 24 V power supply unit Current loading maximum 5 V 8 A 5 V 0 5 A 12 V 4 A 12 V 0 5 A 3 3 V 4 A 5 V VSB 0 5 A Pin assignmen...

Page 14: ...the included material for assembling the connectors Assembling the connector The connector is specified for 16 A and can lift conductive cross sections until 2 5 mm2 Fitting the connector to the cable...

Page 15: ...ur distribution voltage into account so that is secured that the voltage doesn t fall under 22 V at the power supply Insert Fuse The power supply must be protected with 16 A PC_ON Power Status The cir...

Page 16: ...evices that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected C...

Page 17: ...ausing damage by switching off while the software is running is very high Warning When you have shut down the Industrial PC you have to switch off power supply for at least 10 seconds before rebooting...

Page 18: ...CD provided on the Industrial PC Driver archive for the Industrie PC C9900 S700 xxxx There you also find the help file TcUpsShellExt chm before the installation of the software Start the driver softwa...

Page 19: ...to be replaced according to the rules of the board manufacturer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer...

Page 20: ...ncorrect Other cause Remove floppy disk or CD and press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault...

Page 21: ...eckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services world wide sup...

Page 22: ...Dimensions a b t CP7110 10 Display 353 8 308 3 29 5 CP7111 12 Display 353 8 326 3 29 5 CP7112 13 Display 426 395 30 5 CP7113 19 Display 504 455 47 Numerical keyboard Dimensions a b t CP7120 10 Display...

Page 23: ...during transport and storage as in operation Suitable packaging of the Control Panel can improve the resistance to impact during transport The ambient temperature during storage and transport must be...

Reviews: