Transport and storage
CU8130-0120
10
Version: 1.0
3
Transport and storage
NOTE
Short circuit due to moisture
Moisture can form during transport in cold weather or in the event of large temperature fluctuations. Leave
the device to adjust to room temperature slowly. If condensation has occurred, wait at least 12 hours before
switching on the device.
Transport
Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts.
Therefore, during transport please protect your device from:
• mechanical stress and
• use the original packaging.
Table 1: Dimensions and weight
CU8130-0120
Dimensions (W x H x D)
60 mm x 100 mm x 90 mm
Weight
approx. 800 g
Storage
Observe the following storage conditions, in order to maintain the service life of the UPS:
• Store the UPS at room temperature or below.
• Do not store the UPS in a dusty environment, at high humidity or in location with strong vibrations.
• Store the UPS in a charged state.
If the UPS is stored for longer, it must be recharged at regular intervals. Recharge the UPS after 12 months
at the latest. Avoid deep discharge of the UPS.
Summary of Contents for CU8110-0120
Page 1: ...Manual EN CU8130 0120 Uninterruptible Power Supply Battery backed 1 14 2021 Version 1 0 ...
Page 2: ......
Page 56: ......