Diagnosis
EL3783
167
Version: 1.1
Text ID
Type
Place
Text Message
Additional comment
0x8000
Error
System
%s: %s
0x8001
Error
System
Error: 0x%X, 0x%X, 0x
%X
General error; parameters depend on event. See de-
vice documentation for interpretation.
0x8002
Error
System
Communication aborted Communication aborted
0x8003
Error
System
Configuration error: 0x
%X, 0x%X, 0x%X
General; parameters depend on event.
See device documentation for interpretation.
0x8004
Error
System
%s: Unsuccessful Fw-
dOpen-Response re-
ceived from %d.%d.%d.
%d (%s) (Error: %u)
0x8005
Error
System
%s: FwdClose-Request
sent to %d.%d.%d.%d
(%s)
0x8006
Error
System
%s: Unsuccessful Fwd-
Close-Response re-
ceived from %d.%d.%d.
%d (%s) (Error: %u)
0x8007
Error
System
%s: Connection with %d.
%d.%d.%d (%s) closed
0x8100
Error
General
Status word set: 0x%X,
%d
Error bit set in the status word
0x8101
Error
General
Operation mode incom-
patible to PDO interface:
0x%X, %d
Mode of operation incompatible with the PDO interface
0x8102
Error
General
Invalid combination of In-
puts and Outputs PDOs
Invalid combination of input and output PDOs
0x8103
Error
General
No variable linkage
No variables linked
0x8104
Error
General
Terminal-Overtempera-
ture
The internal temperature of the terminal exceeds the
parameterized error threshold. Activation of the termi-
nal is prevented
0x8105
Error
General
PD-Watchdog
Communication between the fieldbus and the output
stage is secured by a Watchdog. The axis is stopped
automatically if the fieldbus communication is inter-
rupted.
- The EtherCAT connection was interrupted during op-
eration
- The Master was switched to Config mode during op-
eration
0x8135
Error
General
Cycle time has to be a
multiple of 125 µs
The IO or NC cycle time divided by 125 µs does not
produce a whole number
0x8136
Error
General
Configuration error: in-
valid sampling rate
Configuration error: Invalid sampling rate
0x8137
Error
General
Electronic type plate:
CRC error
Content of the external name plate memory invalid.
0x8140
Error
General
Sync Error
Real-time violation
0x8141
Error
General
Sync%X Interrupt lost
Sync%X Interrupt lost
0x8142
Error
General
Sync Interrupt asynchro-
nous
Sync Interrupt asynchronous
0x8143
Error
General
Jitter too big
Jitter limit violation
0x817F
Error
General
Error: 0x%X, 0x%X, 0x
%X
0x8200
Error
Communication
Write access error: %d,
%d
Error while writing
0x8201
Error
Communication
No communication to
field-side (Auxiliary volt-
age missing)
- There is no voltage applied to the power contacts
- A firmware update has failed
0x8281
Error
Communication
Ownership failed: %X
0x8282
Error
Communication
To many Keys founded
0x8283
Error
Communication
Key Creation failed: %X
0x8284
Error
Communication
Key loading failed
0x8285
Error
Communication
Reading Public Key
failed: %X
0x8286
Error
Communication
Reading Public EK
failed: %X
0x8287
Error
Communication
Reading PCR Value
failed: %X