Product overview
EL6601, EL6614
32
Version: 4.2
Fig. 36: Insertion of the EL66xx in the Configuration
• The Ethernet port is detected after "Reload I/O devices" (F4) and then appears under network
connections
• as "Local Area Connection 4"
Fig. 37: New Network “Local Area Connection” in the Windows network connections
• The port can now be configured as required. The settings are applied and saved. Even if the port
disappears again, the settings are retained for subsequent commissioning.
If the problem persists, i.e. if the Ethernet port of the EL66xx still fails to show up in the network connection,
see troubleshooting tips below. Follow these tips and the countermeasures listed.
Prerequisites
Check the following:
Virtual Ethernet switch is not enabled
Check the
and the
corresponding notes
TwinCAT2 and TwinCAT3 are installed
simultaneously
Possible driver conflict, please contact Beckhoff support