8. Different measures are available for optimizing the performance of the drive: using lighter materials or
hollow instead of solid body, reducing mechanical mass. The control system can also have significant
influence on the behavior of the drive. The Bus Terminal enables operation with different supply volt-
ages. The characteristic torque curve can be extended by increasing the voltage. In this case, a cur-
rent increase factor can supply a higher torque at the crucial moment, while a general reduction of the
current can significantly reduce the motor temperature. For specific applications, it may be advisable
to use a specially adapted motor winding.