Configuration software KS2000
KL2532/KS2532, KL2552/KS2552
43
Version: 3.2.0
Automatic overload shutdown active (R32.9 [
Here you can activate automatic overload shutdown (default: inactive).
Velocity controller
Kp factor (R37 [
58] only KL2552)
Here you can specify the Kp factor (proportional part) for the internal velocity control (default: 0.1).
Ki factor (R38 [
58] only KL2552)
Here you can specify the Ki factor (integral part) for the internal velocity control (default: 0).
Inner window for I-controller active (R33.4 [
58] only KL2552)
Here you can activate the inner window for the I-controller (default: inactive) and the threshold from which
the inner window is activated (default: 0 %).
External window for I-controller active (R33.5 [
58] only KL2552)
Here you can activate the inner window for the I-controller (default: inactive) and the threshold up to which
the inner window is activated (default: 0 %).
Ka factor (R54 [
60] only KL2552)
Here you can specify the Kp factor (a-part) for the internal velocity control (default: 0).
Kd factor (R55 [
60] only KL2552)
Here you can specify the Kd factor (differential part) for the internal velocity control (default: 0).
Encoder
Input filter active (R32.12 [
Here you can deactivate the input filters for the encoder inputs disable (default: active).
increments per revolution (R42 [
58] only KL2552)
Here you can specify the number of increments per revolution for the connected encoder (default: 0).
Motor data
Maximum coil current (R34 [
58])
Here you can specify the maximum motor coil current (default: 8000 mA).
Reduced coil current (positive direction of rotation) (R41 [
58])
Here you can specify the reduced motor coil current (default: 5000 mA), see description of registers
,
and
.
Threshold for current reduction (positive direction of rotation) (R45 [
Here you can specify the threshold from which automatic current reduction is enabled (default: 100 %).