Access from the user program
KL2532/KS2532, KL2552/KS2552
57
Version: 3.2.0
Legend
Bit
Name
Description
default
R32.13 -
R32.15
-
reserved
R32.12
disEncoder filter
1
bin
Input filter for encoder signals deactivated
0
bin
R32.11
-
reserved
R32.10
enAutoReduce
0
bin
The torque can be reduced manually with bit
0
bin
1
bin
The torque is reduced automatically (see also
R32.9
enOverCurrentErr
or
0
bin
Overload (R0.9 = 1) generates a warning (
0
bin
1
bin
Overload (R0.9 = 1) generates an error (
), and the channel is disabled
R32.3 - R32.8 -
reserved
R32.2
disWatchdog
1
bin
Internal 100 ms watchdog deactivated
0
bin
R32.0 - R32.1 -
reserved
R33: Feature register 2
The feature register 2 specifies the terminal's configuration.
Bit
R33.15 R33.14 R33.13
R33.12
R33.11
R33.10
R33.9
R33.8
Name
-
-
-
-
-
-
-
-
Bit
R33.7
R33.6
R33.5
R33.4
R33.3
R33.2
R33.1
R33.0
Name
-
-
enOuter Window enInner
Window
Operation Mode
Legend
Bit
Name
Description
default
R33.6 - R33.15 -
reserved
R33.5*
enOuter
Window
1
bin
Outer window of the I component of the internal
velocity control active
0
bin
R33.4*
enInner
Window
1
bin
Inner window of the I component of the internal
velocity control active
0
bin
R33.0 - R33.3
Operation
Mode
0
dez
DIRECT MODE Direct duty cycle control proportional
to the process data
0
dez
1
dez
VELOCITY
MODE
Set velocity specification via the
process data proportional to the set
rated speed in
3
dez
reserved
14
dez
reserved
15
dez
CHOPPER
MODE
Existing overvoltage (10% > rated
voltage
connected chopper resistor
*) These settings are only supported by the KL2552, not by the KL2532