Access from the user program
KL6224
48
Version: 2.0.0
Register page 5 (RP5): Parameter(s) for channel 2 (IO-Link device 2)
Structure like
Register page 6 (RP6): Parameter(s) for channel 3 (IO-Link device 3)
Structure like
Register page 7 (RP7): Parameter(s) for channel 4 (IO-Link device 4)
Structure like
Register page 8 (RP8): CMD/status interface and acyclic data for IO-Link device
KL6224 reg-
isters
Description
Name
Comment
RP8.R32
Cmd
TACYCLICKBUSCMD_CMD_START
0x00000001
TACYCLICKBUSCMD_CMD_ACK
0x00000002
TACYCLICKBUSCMD_CMD_READ_CH1
0x00000010
TACYCLICKBUSCMD_CMD_READ_CH2
0x00000020
TACYCLICKBUSCMD_CMD_READ_CH3
0x00000030
TACYCLICKBUSCMD_CMD_READ_CH4
0x00000040
TACYCLICKBUSCMD_CMD_WRITE_CH1
0x00000100
TACYCLICKBUSCMD_CMD_WRITE_CH2
0x00000200
TACYCLICKBUSCMD_CMD_WRITE_CH3
0x00000300
TACYCLICKBUSCMD_CMD_WRITE_CH4
0x00000400
TACYCLICKBUSCMD_CMD_SCAN_CH1
0x00001000
TACYCLICKBUSCMD_CMD_SCAN_CH2
0x00002000
TACYCLICKBUSCMD_CMD_SCAN_CH3
0x00003000
TACYCLICKBUSCMD_CMD_SCAN_CH4
0x00004000
RP8.R33
Status
TACYCLICKBUSCMD_STATUS_IDLE
0x00000000
TACYCLICKBUSCMD_STATUS_BUSY
0x00000001
TACYCLICKBUSCMD_STATUS_DATAREAD
Y
0x00000002
TACYCLICKBUSCMD_STATUS_DATAERRO
R
0x00000003
RP8.R34
SPDU / ISDU SubIdx
SPDU / ISDN
index
RP8.R35
LowByte
Length
Length of the
data
HighByte
SPDU / ISDU SubIdx
SPDU / ISDN
subindex
RP8.R36
Acyclic data for the IO-
Link device
...
RP8.R61
Register page 9 (RP9): Further acyclic data for the IO-Link device
KL6224 registers
Description
Value
Comment
RP9.R0
Further acyclic data for the IO-Link device
...
RP9.R61