Product description
EL6910
15
Version: 1.8.0
3.3
Technical data
Product designation
EL6910
Number of inputs
0
Number of outputs
0
Status display
4 diagnostic LEDs
Minimum/maximum cycle time
approx. 1 ms / according the project size
Fault response time
≤ watchdog times
Watchdog time
min. 2 ms, max. 60000 ms
Input process image
Dynamic, according to the TwinSAFE configuration in TwinCAT 3
Output process image
Dynamic, according to the TwinSAFE configuration in TwinCAT 3
Supply voltage (SELV/PELV)
24 V
DC
(–15% / +20%)
Current consumption via E-bus
approx. 160 mA
Power dissipation of the terminal
typically 1 W
Dimensions (W x H x D)
12 mm x 100 mm x 68 mm
Weight
approx. 50 g
Permissible ambient temperature (operation)
-25°C to +55°C (see notes in section
Permissible ambient temperature (transport/storage)
-40 °C to +70 °C
Permissible air humidity
5% to 95%, non-condensing
Permissible air pressure (operation/storage/transport)
750 hPa to 1100 hPa
(this corresponds to an altitude of approx. -690 m to 2450 m above
sea level, assuming an international standard atmosphere)
Climate category according to EN 60721-3-3
3K3
(the deviation from 3K3 is possible only with optimal environmental
conditions and also applies only to the technical data which are
specified differently in this documentation)
Permissible level of contamination according to EN 60664-1
Contamination level 2 (note chapter
)
Inadmissible operating conditions
TwinSAFE Terminals must not be used under the following operat-
ing conditions:
• under the influence of ionizing radiation (exceeding the
natural background radiation)
• in corrosive environments
• in an environment that leads to unacceptable soiling of the
Bus Terminal
Vibration / shock resistance
conforms to EN 60068-2-6 / EN 60068-2-27
EMC immunity / emission
conforms to EN 61000-6-2 / EN 61000-6-4
Shocks
15 g with pulse duration 11 ms in all three axes
Protection class
IP20
Permitted operating environment
In the control cabinet or terminal box, with minimum protection
class IP54 according to IEC 60529
correct installation position
Installation position and minimum distances [
Approvals
CE, cULus, TÜV SÜD
Summary of Contents for TwinSAFE EL6910
Page 1: ...Operation Manual for EL6910 TwinSAFE Logic Terminal 1 8 0 2019 01 09 Version Date...
Page 2: ......
Page 69: ...Operation EL6910 69 Version 1 8 0 Fig 73 The Safety Project Online View tab...
Page 136: ...Appendix EL6910 136 Version 1 8 0 5 2 Certificates...