Technical data, mounting, wiring
PS2001-2410-0000
17
Version: 1.0
3.7
Efficiency and losses
AC 100V
AC 120V
AC 230V
Efficiency
Typ.
92.9%
93.6%
95.2%
At 24V, 10A
Typ.
92.5%
93.4%
95.1%
At 24V, 12A (Extra Power)
Average efficiency
*)
Typ.
92.5%
93.0%
94.3%
25% at 2.5A, 25% at 5A,
25% at 7.5A. 25% at 10A
Losses
Typ.
2.5W
2.1W
1.8W
At 24V, 0A
Typ.
9.8W
8.9W
7.1W
At 24V, 5A
Typ.
18.3W
16.4W
12.1W
At 24V, 10A
Typ.
23.4W
21.7W
14.8W
At 24V, 12A (Extra Power)
*)
The average efficiency is based on assumptions for a typical application with the power supply unit
operating at 25% of the nominal load during 25% of the time, 50% of the nominal load during 25% of the
time, 75% of the nominal load during 25% of the time and 100% of the nominal load during the remaining
time.
Fig. 10: Efficiency over output current; losses over output current
Fig. 11: Efficiency over input voltage; losses over input voltage