Pole top - indirect

77 210

Tools Required:

5mm hex key

6mm hex key

8mm hex key

Adjustable wrench

Protection Class: 

IP65

Weight:

  50.0 lbs.

Dimensions
A:

    39-3/8 “

B:

    22-5/8 “

Relamping/Maintenance

NO relamping required.

Lamp:

   55.3W LED 

   77 210

10/9/2018

Page 1 of 2

Description

Lens

Lens gasket 

Driver (120-277V)

LED Module (3000K)

LED Module (4000K)

Part No

140878

830647 

75976

LED-0721/830

LED-0721/840

Notice to Installer for 77 210:

1. Do not open luminaire.

2. For pole top applications only.

3. Slip fits 3” O.D. pole top or tenon.

4. Luminaire requires at least 3-1/2” of straight diameter pole or tenon.

77 210 assembly:

1. Loosen the (2) 8mm hex screws at the top of the support rods and remove  

   

     

    screws and fixing plates. 

2. Attach the reflector disk to the support rods by positioning the joint shells over the  

     

    joint bearings. Make sure the drip edges are oriented downwards.  

3. Replace the fixing plates and screws.

4. Tilt the reflector to the desired orientation (0-30 degrees).  Consult factory for        

     

    non-adjustability option.

5. Tighten the (2) 8mm screws to secure in place.

77 210 - installation:

1. Carefully hinge down pole, exposing bottom of pole.

2. Route the luminaire wiring through to the pole top base and slip luminaire over 

    the top of the pole.

3. Tighten the (8) 5mm set screws evenly to secure to pole. 

4. Make wiring connections from luminaire wires to gear tray wires by attaching the 

    (2) quick-connect terminals securely.

  

NOTE: ONLY attach luminaire wires to specifi ed gear tray wires. 

5. Place the gear tray in the base of the pole and tighten the 5/16” hex bolt to wedge 

    inside pole and secure.

6. Make supply wiring connections to gear tray wires:

  

MAIN VOLTAGE SUPPLY WIRE TO BLACK DRIVER WIRE

  

NEUTRAL (COMMON) SUPPLY WIRE TO WHITE DRIVER WIRE

  

GREEN GROUND WIRE TO GREEN DRIVER WIRE

    Dimming (if applicable):

  

DIMMING CONTROL WIRE (+) TO POSITIVE LUMINAIRE DIM   

 

 

CONTROL WIRE

  

DIMMING CONTROL WIRE (-) TO NEGATIVE LUMINAIRE DIM  

 

 

 

CONTROL WIRE

7. Replace pole to upright position and secure by tightening (3) base bolts.

  

IMPORTANT: PLEASE NOTE THE WEIGHT OF LUMINAIRE HEAD ON 

  

POLE AND TAKE CAUTION ACCORDINGLY DURING POLE TILT.

     

indirect cutoff optics

/

Pole top w

suitable for wet locations.

6mm and 8mm Hex Keys
Adjustable Wrench

BEGA

Installation and Technical Information

Tools Required:

Dimensions

A:
B:

39-3/8 " 

24-1/4 " 

UL listed,

  IP 65

50.0 lbs

Protection Class: 

Weight:

8309MH

Notice to Installer for 8309MH:

Luminaire slip fits a 3" O.D. pole top.

1.

Luminaire requires ballast mounted in minimum 5" butt hinge base pole. NOTE:  Lower pole 
before installing luminaire and ballast tray.

2.

8309MH assembly:

Loosen (2) M8 socket head screws and remove cover ring and glass with gasket.

1.

Insert lamp.

2.

Replace glass with gasket. Make sure the grooved side of the glass fits the underside of the 
cover ring.  Otherwise, flip the glass.  And make sure the gasket is seated flush to ensure 
proper seal.

3.

Tighten the (2) M8 screws evenly.

4.

Loosen the (2) M10 socket head screws at the top of the support rods and remove screws 
and fixing plates.

5.

Attach the reflector disk to the support rods by positioning the joint shells over the joint 
bearings.  Make sure the drip edges are oriented downwards.

6.

Replace the fixing plates and screws.

7.

Tilt the reflector to the desired orientation (0-30º).  Consult factory for non-adjustability 
option.

8.

Tighten the (2) M10 screws to secure in place.

9.

8309MH installation:

Route the luminaire wiring through to the pole base and slip the pole top base over the top 
of the pole.

1.

Tighten the (8) M10 set screws evenly to secure to pole.

2.

Make wiring connections from luminaire wires to ballast tray wires:
BLACK LUMINAIRE WIRE TO BLACK MARKED "SOCKET" WIRE
WHITE LUMINAIRE WIRE TO WHITE MARKED "SOCKET" WIRE 
GREEN LUMINAIRE WIRE TO GREEN GROUND WIRE

3.

Place the ballast tray in the base of the pole and tighten the 5/16" hex bolt to secure.

4.

Make supply wiring connections to ballast tray wires:
MAIN VOLTAGE SUPPLY WIRE TO BLACK BALLAST WIRE
NEUTRAL (COMMON) SUPPLY WIRE TO WHITE BALLAST WIRE
GREEN GROUND WIRE TO GREEN BALLAST WIRE

5.

Relamping/Maintenance

Accessories

Replacement Parts

Lamp:
Philips :

Osram/Sylvania :

GE :

MC150T6/U/G12

CMH150/T/U/G12

CDM150/T6

Disassemble cover ring and glass. Clean dirt and 
deposits from the luminaire and glass using only 
solvent-free cleaners. Relamp and replace gasket if 
damaged. Reassemble cover ring and glass.

Description

Part No

Diffuser
Gasket
Lampholder
Ballast (120V/208V/240V/277V)

140273
830647

74121
75146

(1) 150W T6 G12 MH

Please refer to the appropriate 
accessory installation sheet for 
further instruction when applicable.

In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
BEGA

 

1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA/US 2004

2/2/2006

8309MH

Reviews: