English
⋅
Nautilus
®
CC plus
57
A
en
The chamber is evacuated during preheating.
The preheating may last for up to 60 seconds.
9.
Have the mould readily available before press-
ing the "OK" button to prevent the alloy from
cooling down unnecessarily. The preheating
temperature and vacuum are maintained until
then.
10. Close the mould door.
The next display is shown when the mould
door is closed.
11. Confirm the melting process with "OK".
In fast mode, the next step is triggered immedi-
ately when the mould door is closed.
The process can be aborted by pressing the
"Abort" button.
ATTENTION
The temperature cannot be
measured and therefore cannot be
limited without the pyrometer!
Stay with the device and finish the
preheating and melting as described
manually!
WARNINGS
Risk of burn injuries!
Use mould tongs!
WARNINGS
Never look into the melt without
protective glass and protective
eyewear!