English
⋅
Eltropol 300
35
85
95
5 B
A
-en
/1
1
en
Changing the polishing solution
The more it is used, the less effective the polishing
solution becomes. The unit calculates and displays
the optimum point at which to renew the solution.
•
LED blinks: change solution soon.
•
LED lights up: change solution now.
1.
Switch off the unit at the main switch and pull
the plug out.
2.
Carefully turn the unit around without tipping it
in order to reach the drainage tube on the back
of the unit.
3.
Pull the drainage tube out of the clamp, hold it
upright and remove the stopper. Lower the
tube into a suitable canister with a capacity of
at least two litres and allow the polishing solu-
tion to drain off. Use a funnel if necessary.
WARNING
ATTENTION!
Wirolyt contains glycol and
sulphuric acid!
• Avoid contact with skin and eyes!
Risk of blinding!
• Wear safety glasses and safety
gloves!
Never add water!
• Dispose of as hazardous waste!
Used Wirolyt contains heavy metal
ions – do not allow it to enter the
sewer system!
WARNING
Risk of scalding!
• The operating temperature of
Wirolyt can reach 40-60 °C!