Fundor T
5
Special safety instructions regarding this unit
Installation
l
The unit is categorised under protection class 1 and may only be connected to properly earthed power
sources (earth contact sockets).
l
Only a trained worker is allowed to install the Fundor T.
Fundor T has go to be placed horizontally on a level working bench.
l
When laying cables and hoses, ensure that they are protected from hot components (e.g., moulds).
l
It is absolutely necessary to note the safety an danger pecautions in the instructions for use when
installind and starting of Multiplex and automatic gas lighter.
Working
l
The counterweight of the mould ist to be correctly adjusted in the clicking points in order
to prevent the out-of-balace and so a moving of the machine when centrifugal casting.
Danger of burns due to hot parts!
l
Wear protective clothing (protective apron), safety shoes, safety goggles and protective gloves.
l
Always use mould tongs to move moulds and hot crucibles.
l
Place hot parts only on a fireproof surface.
l
Carry out maintenance and cleaning work prior to casting or once the unit has cooled down.