General Information .............................................21

Unpacking / Packing ............................................23

Safety Instructions................................................24

Unit description ....................................................26

Scope of delivery, wearing parts and extras ........28

Technical Data......................................................28

Installation ............................................................29

Check set temperatures .......................................29

Filling....................................................................30

Switching on and duplicating................................31

Timer ....................................................................32

Care .....................................................................33

Elimination of malfunctions ..................................34

Signs, labels and stickers.....................................35

Disposal ...............................................................36

Spare parts list ..........................................Appendix

Wiring diagram ..........................................Appendix

Certificate of Conformity............................Appendix

GOST certificate........................................Appendix

This unit documentation is part of the unit 

and must be enclosed when selling or 

passing on the unit.

The unit has been designed solely for use in 
dental laboratories and comparable establish-
ments for research, commercial and training 
purposes. The unit must only be operated by 
dental professionals, or they must provide 
supervision if trainees or other persons operate 
unit.

The operating instructions must be read and 
understood before the device is used. This par-
ticularly applies to the 

Safety information.

 The 

warranty is void in cases of damage which is 
caused by non-observance of the operating 
instructions. We will also not accept liability for 
any resulting consequential damages.

Symbols used

This symbol indicates very important 
information. Failure to comply with it 
may result in personal injury.

This symbol warns about hot parts.

Warning of dangers from electric 
voltage!

Summary of Contents for Gelovit 200

Page 1: ...Translation of the original instructions Gelovit 200 en English Gelovit 200 334 00171 ...

Page 2: ...ing on the unit The unit has been designed solely for use in dental laboratories and comparable establish ments for research commercial and training purposes The unit must only be operated by dental professionals or they must provide supervision if trainees or other persons operate unit The operating instructions must be read and understood before the device is used This par ticularly applies to t...

Page 3: ...ting instructions We welcome any suggestions or criticism Please feel free to notify us Your effort will help us make the operating instructions more user friendly and respond more effectively to your wishes and needs Target group This document is directed toward everyone who works with this device or performs service tasks that are described in this document Contact information BEGO Bremer Goldsc...

Page 4: ...owed or not followed properly WARNING This reference identifies hazards that can cause bodily injury or property damage if the relevant hazard instruc tions are not followed or not followed properly ATTENTION This reference identifies only those hazards that are potential damaging to property and the environment NOTE This symbol identifies user tips and particularly useful information It helps you...

Page 5: ...roper installation putting into operation operating and maintenance of the device Operating the device with safety and protective facilities that are defective improperly installed or inoperative Failure to heed the information in this manual concerning the transport storage installation putting into operation operation and service and maintenance of this device Unauthorized structural modificatio...

Page 6: ...only be operated by staff members who are familiar with and follow the instructions of this operating manual The operating manual must be easily accessible when the machine is operated Observe the national accident prevention regulations in addition to this operating manual Handling the machine Prior to the electrical connection check whether the specifications on the rating plate correspond to th...

Page 7: ...er every intervention in the machine Germany check in accordance with DIN VDE 0701 1 only qualified electricians may open the machine Only BEGO replacement and wearing parts may be used Special safety instructions regarding this machine WARNING Burn hazard from hot parts During the melting process the housing and cover become hot Let the unit cool down or use safety gloves before touching the cove...

Page 8: ...irodouble Provision time The melting and cooling down of 6 kg of duplicating material to the operating temperature takes 3 to 4 hours depending on the duplicating material used and the manufacturer Built in timer By means of a timer the unit can be set for the night so that duplicating material is available at operating temperature at the beginning of the next working day Quality assurance Gelovit...

Page 9: ... T2 Set T1 Cooling heating to T2 Set T2 Cooling to T3 Set T3 1 for settings Hold down both buttons simultaneously to reset the counter for melting operations actual number to zero RESET 1 for settings Display number of melting operations Example 01 08 01 Actual number melting operations so far 08 Max number maximum recom mended melting operations Set max number Switch timer on off Setting the time...

Page 10: ...ories REF Castrogel 6 kg tub 52052 Wirodouble 6 kg tub 52050 Wirogel M 6 kg tub 54351 Technical Data Height 565 mm Width 310 mm Depth 355 mm Weight 21 kg Nominal voltage 230 VAC 50 60 Hz Special voltage 100 240 VAC 50 60 Hz Noise emission 70 dB A Max power consumption 900 VA Ambient temperature 15 30 C on request NOTE The spare parts list is appended When ordering spare parts please quote the REF ...

Page 11: ...irogel M cannot be processed at reduced temperature The factory setting of the temperature display is in C To change over to F call Customer Service WARNING Property damage The unit may only be installed on an adequately stable surface The unit may only be used in an enclosed space WARNING Electrical hazard Prior to the electrical connection check whether the specifications on the rating plate cor...

Page 12: ...ouching the cover Be careful when reaching into the container Pull out the mains plug before reaching in The agitator has sharp edges The container may be very hot NOTE Used duplicating material can be re utilised but must first be melted Clean used duplicating material carefully with water Do not put used duplicating material in the container until imme diately before the next melting operation D...

Page 13: ... after operating temperature has been reached duplicating material is cooled down to the reduced operating temperature and is heated up to operating temperature again 10 minutes later Lamp T3 flashes or is constantly lit reduced operating temperature not yet reached or has been reached Press the button briefly to display the number of melting operations Example 01 08 01 Actual number melting opera...

Page 14: ...oustic signal sounds twice then release it the last time hours set is displayed 2 If necessary change the time by pressing the and buttons Only full hours can be set Holding the button down accelerates the adjustment procedure The time is saved after approx 4 seconds 3 To start the timer press button briefly The display shows the remaining time until the unit is switched on hours minutes Lamps T1 ...

Page 15: ...housing with water and mild cleaning agent Do not use cleaning agents in the dupli cating material container DANGER Warning of electric shock Danger to life Switch off the machine and pull out the mains plug before performing any care or maintenance work In the case of power connection without mains plug remove fuses secure machine so it cannot be switched on again and check that it is de energize...

Page 16: ...witched on The fuse of the unit is defective Replace fuses on right side of unit If fault occurs again contact Customer Service Department The mains socket is defective Check socket No display but acoustic signal SOS Display defective Contact customer service Lamp next to the button flashes The last set melting operation takes place Duplicate as usual Before switching off the unit remove old dupli...

Page 17: ...English Gelovit 200 35 85980 BA en 05 334 00171 en Signs labels and stickers ...

Page 18: ...ic waste As a customer you contribute to the protection of the environment when you dispose of the device correctly Disposal in Germany BEGO offers you a disposal solution for all BEGO devices sold and put into operation in Germany subsequent to August 13 2005 Please contact us when it is time to dispose of the device Disposal in other countries of the European Union Please contact the company fro...