Operation
General instructions
The following sections describe how to handle the
unit. The symbols and fonts used in the description
are explained in the section
→
CONVENTIONS.
Workplace
The device is designed so that the operator can
easily reach all the necessary operating elements
while seated, provided that the device is placed on
a suitable table.
Turning on the unit
Fig. 26
Main switch and key switch
1.
Make sure that the LASER key switch (B) is in
"0" position ((C) in Fig. 26).
2.
Set the main switch (A) (on the back) to the "I"
position.
3.
Turn the LASER key switch (B) to the middle
position (D).
The pump of the cooling system starts.
4.
Wait for about 1 second (until the supply vol-
tages are ready).
5.
Temporarily turn LASER key switch (B) into
START position (E), and than release back to
(D) position.
The laser lamp power supply is switched on
and the flash lamp is ignited.
WARNING
If smoke or gases are emitted when
working with the laser, you must not
continue working with a defective
exhauster.
There is a risk of hazardous gases
escaping from the working chamber.
Moreover optical components might
be polluted and irreparably damaged.
WARNING
Burn hazard!
Before using the device, find a sitting
position that allows you to work in a
relaxed manner. In particular, the
freely-moving footswitch should be
placed in a suitable position to prevent
laser pulses from being unintentionally