64
860
76
D
B
-en/
03
35
5.0
00
32
English
⋅
LaserStar T Plus
en
Setting combinations
* If different alloys are welded together, always use the higher-quality filler metal.
•
All values indicated are only reference values and a basis for your own tests!
•
Feed argon correctly to the welding point!
Service Tel.: +49 421 2028-282 / -379
Situation
Voltage
V
Time
ms
Focal
point
Ø
Filler metal of
the same type
necessary?*
1 Clasp break partial denture (Co-Cr)
270
4,0
0,6
yes
Partial denture
2 Break in sublingual bar (PD)
280
4,0
0,4
3 Cavity in partial denture frame
280
4,0
0,7
4 Retentions (bent) to partial denture
270
6,0
0,7
5 Upper-jaw base extension
270
4,0
0,6
6 Precious-metal secondary crown to partial denture
290
9,0
0,6
7 Precious metal bar sleeve to partial denture
290
8,0
1,0
8 Anchor / attachment male parts to partial denture
300
8,0
1,2
9 Build up crown border (Precious metal)
270
3,0
1,0
yes
Precio
u
s metal
10 Defects in precious-metal crowns
280
4,0
1,2
11 Weld precious-metal bridge
290
10,0
0,4
12 Align precious-metal bridge
290
6,0
1,0
no
13 Build up contact points (precious metal)
290
4,0
1,2
yes
14
Precision pins for friction to telescopic crowns (pre-
cious metal)
280
4,0
1,2
no
15
Increase friction of secondary crowns (precious
metal)
260
2,5
1,0
no
16 Dolder bar to crown (precious metal)
270
2,5
1,0
yes
17 Build up crown border (non-precious)
240
5,0
0,4
yes
Non-precious
18 Fill cavities in non-precious crowns
270
5,0
0,5
19 Weld non-precious bridges
280
5,0
0,4
20 Align non-precious bridges
300
5,0
0,8
no
21 Weld palladium-base crowns together
290
7,5
0,6
yes
Pd
22 Partial denture to palladium-base crowns
280
6,5
0,6
23 Clasp break partial denture (titanium)
270
2,5
1,0
no
Titanium
24 Break lingual bar (titanium)
260
3,0
0,8
yes
25 Weld titanium bridge
300
3,5
1,0
no
26 Titanium: bar to implant
280
2,5
1,2
no
27 Titanium to precious metal
290
3,0
1,2
yes
28 Weld orthodontic wires
240
3,0
1,2
yes
KFO