Installation
Fig. 3
Installation Regulus
WARNING
Installation, site of Installation
and start-up
•
Install unit only on adequately sta-
ble and non-combustible surface.
•
Because of the wax vapours, install
the furnace under a chimney stalk
as far as possible.
Always dis-
charge vapours outdoors.
•
Only use the furnace in dry rooms.
•
There must not be any combustible
objects in the area near the fur-
nace.
•
There must not be any highly flam-
mable or explosive gas, liquids or
solid material in the same room as
the furnace.
WARNING
Danger due to electric shock
•
Prior to the electrical connection
check whether the specifications on
the rating plate correspond to the
power supply network. In the case
of uncertainty, consult an electri-
cian.
•
Always connect the furnace to a
separate circuit with 16-ampere
fuse protection.
•
The machine is subject to the provi-
sions of class of protection I and
may only be connected to properly
grounded power sources.
•
Use the rear plug only for connect-
ing the Regulus furnace suction
extraction unit (REF 25750,
200…240 V).
•
If moulds are to be preheated using
the shock heat method, the Regulus
furnace extraction system must be
installed!