16
Measuring Diode
X�
Disconnect circuit power and discharge all high-voltage capacitors
before testing diode.
Note:
A typical junction Voltage drops 0.5 V to 0.8 V.
Measuring Temperature °C / °F
X�
1. To avoid personal injury or damage to the meter, do not apply the
temperature probe to any live conductive parts.
2. Temperature sensor K-type (nickel-chromium/nichrosi) thermocouple is
suitable for temperature measurement below 230°C (446°F).
Measurement steps:
Step 1:
Turn the rotary switch to °C/°F position. The display will show
“OPEN”. Press SELECT button for conversion to °F measurement.
Step 2:
Connect the temperature probe (K-type) to the Meter and to the
surface to be measured. Two temperature surface points can be measured
at the same time by using the provided temperature probes.
Step 3:
Press RANGE button to select temperature measurement T2 or T1-T2
(the default temperature measurement is T1).