7B
REV. C
B-3
Table 1-1
CIIL SOFTWARE COMMANDS (cont)
CIIL COMMANDS
EXPLANATION
SRN VOLT <value>
Optional. Sets minimum value limit for SET VOLT command. If SET
VOLT value is less than SRN VOLT value in a command string, an
error message is generated and a setup command ignored. The
following values are permitted:
/0
#
value < 34, or 135, or 27 /0, dependent on range selected and type
of unit.
The SET VOLT default is /0 for the minimum value if a value is not
specified for SRN VOLT.
SRX FREQ <value>
Optional. Sets maximum limit for SET FREQ command. If the SET
FREQ value in a command string is grater than the maximum limit, an
error message is generated and the setup command ignored. Legal
values are:
45 < value
#
5/0/0.
If a value for SRX FREQ is not specified, SRX FREQ defaults to
5/0/0.
SRN FREQ <value>
Optional. Assigns minimum value to SET FREQ command. If the
SET FREQ value in a command string is less than the minimum
limit, an error message is generated and the setup command
ignored. Legal values are:
45
#
value < 5/0/0.
If a value for SRN FREQ is not specified, SRN FREQ defaults to
45.
SET VLT/0
Set LO voltage range.
SET VLT1
Set HI voltage range.
Delay is necessary after issuing setup command, due to output voltage slew rate of 100v per 250 ms.
On dual range Power Supplies, this command selects the LO or HI voltage range. Dual Ranges are
/0-34 volts /0-135 volts and /0-135/ /0-27 /0 volt. If this command is omitted from the setup string the unit
will default to the lowest available range. On single range units this command will be ignored.
NOTE
1. The setup command specifies the voltage and frequency of the AC power Supply output. The AC
Power Supply responds only to the last setup command entry. Its memory does not retain previously
entered setup commands.
2. During IEEE operation, the unit's front panel VOLTS and FREQ controls must be fully CCW. If the
controls are not set fully CCW, then the output voltage and frequency will be a sum of the programmed
value and the value set with the front controls. Front Panel OUTPUT switch must be set to OFF position.
Front Panel RANGE switch (on dual range units) must be set to LO.
Summary of Contents for BL3300 Series
Page 9: ...3 BL3300 SERIES MANUAL 01 28 2013 ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Page 15: ...9 BL3300 SERIES MANUAL 01 28 2013 SECTION 2 UNPACKING AND INSTALLATION ...
Page 17: ...11 BL3300 SERIES MANUAL 01 28 2013 FIGURE 2 2 ...
Page 20: ...14 BL3300 SERIES MANUAL 01 28 2013 ...
Page 33: ...3 PHASE POWER CHASSIS MECHNICAL OUTLINE ...
Page 34: ...BL3300 CONTROL CHASSIS MECHANICAL OUTLINE ...
Page 35: ...BL33XX SERIES SINGLE PHASE POWER CHASSIS OUTLINE DRAWING 19 0 TYP 17 TYP 7 0 MAX ...
Page 54: ...6 1 SECTION 6 PARTS LIST AND DRAWINGS f ...
Page 56: ......
Page 57: ......
Page 58: ......
Page 60: ......
Page 62: ......