7B
REV. C
B-9
3. EXAMPLE: Setup a dual range BL Source to output 115 V on high range @50Hz, and read
back what the actual voltage, current and frequency being output is set at.
Transmit setup command
FNC ACS :CH/0 SET VOLT 115 SET FREQ 5/0 SET BLT1 <cr><lf>
Transmit status command to request status response:
STA <cr><lf>
Talk address the BL Source to enable response:
<space><cr><lf>
:Positive response indicating status is OK.
Transmit output relay close command:
CLS :CH/0 <cr><lf>
Transmit status command to request status response:
STA <cr><lf>
Talk address the BL Source to enable response:
<space><cr><lf>
:Postive response indicating status is OK.
Transmit fetch volt command:
FTH VOLT <cr><lf>
Talk address the BL Source to enable response:
115./0 <cr><lf>
Transmit fetch current command:
FTH CURR <cr><lf>
Talk address the BL Source to enable response:
5.2 <cr><lf>
Transmit fetch frequency command:
FTH FREQ <cr><lf>
Talk address the BL Source to enable response:
5/0./0 <cr><lf>
Summary of Contents for BL3300 Series
Page 9: ...3 BL3300 SERIES MANUAL 01 28 2013 ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Page 15: ...9 BL3300 SERIES MANUAL 01 28 2013 SECTION 2 UNPACKING AND INSTALLATION ...
Page 17: ...11 BL3300 SERIES MANUAL 01 28 2013 FIGURE 2 2 ...
Page 20: ...14 BL3300 SERIES MANUAL 01 28 2013 ...
Page 33: ...3 PHASE POWER CHASSIS MECHNICAL OUTLINE ...
Page 34: ...BL3300 CONTROL CHASSIS MECHANICAL OUTLINE ...
Page 35: ...BL33XX SERIES SINGLE PHASE POWER CHASSIS OUTLINE DRAWING 19 0 TYP 17 TYP 7 0 MAX ...
Page 54: ...6 1 SECTION 6 PARTS LIST AND DRAWINGS f ...
Page 56: ......
Page 57: ......
Page 58: ......
Page 60: ......
Page 62: ......