C-2
1.3
EIA-232 SERIAL COMMUNICATION
The BL Series Power Supply incorporates an EIA-232 serial communications interface,
which allows all function to be programmed and monitored remotely via a host computer.
The Power Supply receives ASCII encoded command strings via a EIA-232 interface
according to MATE System Control Interface Standard No. 2806763 (IEEE-716 CIIL).
The AC Power Supply supports all OPCODES, NOUNS, and MODIFIERS required by
the stimulus module. They are as follows:
OPCODES
FNC, FTH, :CHO, SET, SRX, SRN, CLS, OPN, RST, CNF, IST,STA INX,
MODIFIERS
FREQ, VOLT, CURR, VLT0, VLT1
NOUN
ACS
The BL Series Power Supply can be used in point-to-point mode where a host
Computer is connected irectly to One Power Supply.
NOTES:
1. Leading zeroes must be entered for commands.
2. Leading zeroes are blanked in response transmit.
EXAMPLES:
1.4
AC POWER SUPPLY SYNTAX
Setup Command:
FNC ACS :CHO SET VOLT <value>
[ SET FREQ <value>]
[ SRX VOLT <value>]
[ SRN VOLT <value>]
[ SRX FREQ <value>]
[ SRN FREQ <value>]
[SET VLT(0,1)] <cr><lf><eos>
Table 1-1
CIIL SOFTWARE COMMANDS
(cr) =ASCII ‘ carriage return’ code 0D Hex, ISO keyboard ^M
(lf) =ASCII ‘ line feed ’ code 0A Hex, ISO keyboard ^J
(eos) =ASCII ‘carriage return’ code 1A Hex, ISO keyboard ^Z
ASCII file transfer end-of string command
Summary of Contents for BL3300 Series
Page 9: ...3 BL3300 SERIES MANUAL 01 28 2013 ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Page 15: ...9 BL3300 SERIES MANUAL 01 28 2013 SECTION 2 UNPACKING AND INSTALLATION ...
Page 17: ...11 BL3300 SERIES MANUAL 01 28 2013 FIGURE 2 2 ...
Page 20: ...14 BL3300 SERIES MANUAL 01 28 2013 ...
Page 33: ...3 PHASE POWER CHASSIS MECHNICAL OUTLINE ...
Page 34: ...BL3300 CONTROL CHASSIS MECHANICAL OUTLINE ...
Page 35: ...BL33XX SERIES SINGLE PHASE POWER CHASSIS OUTLINE DRAWING 19 0 TYP 17 TYP 7 0 MAX ...
Page 54: ...6 1 SECTION 6 PARTS LIST AND DRAWINGS f ...
Page 56: ......
Page 57: ......
Page 58: ......
Page 60: ......
Page 62: ......