P1351ieee.wpd
5-1-3
1.1
IEEE-488 BUS UTILIZATION
The P1351 Series Power Supplies incorporates an embedded TMA that is compatible with the
electrical and mechanical standards outlined in IEEE-STD-488. The IEEE-488 interface uses a TI
LSI device to implement all necessary talker/listener functions. This device is configured under
software control to support the following subsets:
SH1
- Source Handshake
AH1
- Acceptor Handshake
T8
- Basic Talker
L4
- Basic Listener
RL1
- Remote/Local
DC1
- Device Clear
SRO
- No Service Request
PPO
- No Parallel poll response
DTO
- No Device Trigger
CO
- Not a controller
1.2
IEEE-488 BUS COMMANDS
1. Single-Line Commands
IFC - Clears GBIB interface
2. Multi-Line Command
DCL - Resets AC Power Supply to the quiescent state if a catastrophic failure is not present. The
only way to clear a catastrophic failure is to read the Power Supply's response by using the
Status command.
1.3
GPIB COMMUNICATION
The embedded TMA receives ASCII encoded command strings via a GPIB IEEE-488 according to
MATE System Control Interface Standard No. 2806763 (IEEE-716 CIIL). Programmed I/O is utilized
to transmit and receive command strings after a talker/listener relationship is established. The AC
Power Supply supports all OPCODES, NOUNS, and MODIFIERS required by the stimulus module.
They are as follows:
OPCODES
FNC, FTH, INX, :CHO, SET, SRX, SRN, CLS, OPN, RST, CNF, IST,STA
MODIFIERS
FREQ, VOLT, CURR
NOUN
ACS