Table 5-2-1
CILL SOFTWARE COMMANDS (cont)
CILL COMMANDS
EXPLANATION
FETCH DATA COMMAND:
FTH VOLT <cr><lf><eos>
The AC supply responds to this command by transmitting the RMS
voltage (in volts) measured at its output, in decimal format as follows:
<sp><digit><digit><digit><dp><digit><digit><cr><lf><eos>
FTH CURR <cr><lf><eos>
The AC Supply responds by transmitting the current (in amps)
measured at its output, in decimal format, as follows:
<sp><digit><digit><dp><digit><cr><lf><eos>
FTH FREQ <cr><lf><eos>
The AC Supply response by transmitting the frequency (in hertz)
measured at its output, in decimal format, as follows:
<sp><digit><digit><digit><cr><lf><eos>
CLS :CH0 <cr><lf><eos>
Closes output relay contacts. Connects AC Power Supply outputs to
output terminal P1351ock. The setup command specifiesthe voltage and
frequency. The setupcommand must be entered before the CLS :CH0
command.
OPN :CH0 <cr><lf><eos>
Opens output relay contacts. Disconnects output of AC Power Supply
from output connector. Ac Power Supply retains voltage and frequency
assigned by setup command.
RST ACS:CH0
Resets AC Power Supply to quiescent. The output relay opens and error
messages are erased.
Catastrophic error messages are cleared by reading the Power Supply's response, by use of the Status
command.
CNF <cr><lf><eos>
Instructs AC Power Supply to perform internal confidence test. STA
command transmits the message. The AC Power Supply responds with
one of the following:
Pass
<sp><cr><lf><eos>
Fail
F07ACS0(DEV): CONFIDENCE TEST FAILURE
<cr><lf><eos>