EN                                                                                                                                                            Terminal Clamp AKL-8-W

 

                                                                      RC-Junky English Conversion                                                                3 

 

Connection example to sound speed controller SFR-1

 

 

 

 

 
 

Connection of LEDs and other components  

 

The connection cables of the consumer/component/light can be connected to the 
spring-loaded terminals of the AKL-8-W. To insert or remove a cable, just press from 
above with a small screwdriver on the operating lever of the terminal. This opens the 
clamp and the cable can be plugged in or out. 
 
The cables should be stripped approx. 7 - 8 mm and be tinned with solder. The cable 
cross-section can be between 0.14 mm² and 1.0 mm². 
 
The switching outputs of the SFR and UFR are negative switching, i.e. the negative lead 
of the consumer is always connected to the outputs 1-8 of the terminal clamp. 
The positive lead of the consumer to output 9 or 10 of the terminal clamp. 
 

The switched voltage at the eight outputs is always as high as the SFR or UFR supply 

voltage! Therefore, it is important to have the correct in series resistors inserted 

in the base of the AKL-8-W (see below)! 

 

 

Input  

6 -18V 

Output 8 
Output 7 
Output 6 
Output 5 
Output 4 
Output 3 
Output 2 
Output 1 

Output 16 
Output 15 
Output 14 
Output 13 
Output 12 
Output 11 
Output 10 