EN Terminal Clamp AKL-8-W
RC-Junky English Conversion 3
Connection example to sound speed controller SFR-1
Connection of LEDs and other components
The connection cables of the consumer/component/light can be connected to the
spring-loaded terminals of the AKL-8-W. To insert or remove a cable, just press from
above with a small screwdriver on the operating lever of the terminal. This opens the
clamp and the cable can be plugged in or out.
The cables should be stripped approx. 7 - 8 mm and be tinned with solder. The cable
cross-section can be between 0.14 mm² and 1.0 mm².
The switching outputs of the SFR and UFR are negative switching, i.e. the negative lead
of the consumer is always connected to the outputs 1-8 of the terminal clamp.
The positive lead of the consumer to output 9 or 10 of the terminal clamp.
The switched voltage at the eight outputs is always as high as the SFR or UFR supply
voltage! Therefore, it is important to have the correct in series resistors inserted
in the base of the AKL-8-W (see below)!
Input
6 -18V
Output 8
Output 7
Output 6
Output 5
Output 4
Output 3
Output 2
Output 1
Output 16
Output 15
Output 14
Output 13
Output 12
Output 11
Output 10
Output 9