Chemical Resistance

4.2.2

Touch Screen Surface

The touch screen surface on the operator panel withstands exposure to the
following solvents without visible change:

Solvents

Time

Acetone

10 minutes

Isopropanol

10 minutes

Toluene

5 hours

4.2.3

Touchscreen Protective Film

Autoflex EB

It is recommended to use the Autoflex EB touch display protection film, that can
be ordered from Beijer Electronics.

Outdoor Use

In common with all polyester based films, Autoflex EB is not suitable for use in
conditions of long-term exposure to direct sunlight.

Note:

The layer structure of the touch screen contains air and in rare cases appearance of
bubbles can arise. This is purely cosmetic and does not affect any functionality of the
panel. The appearance can occur under certain environmental conditions such as
temperature, humidity, and atmospheric pressure.

Beijer Electronics, MAEN165

16

Summary of Contents for 640003701

Page 1: ...T15BR Installation Manual English MAEN165 2014 04...

Page 2: ...group companies assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only quali ed personnel may i...

Page 3: ...rals 11 3 TechnicalData 12 4 ChemicalResistance 14 4 1 MetalCasing 14 4 2 Touch Screen and Overlay 15 4 2 1 Auto ex EB 15 4 2 2 Touch Screen Surface 16 4 2 3 Touchscreen Protective Film 16 4 3 Termina...

Page 4: ...powerful irritant Incase of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserves a...

Page 5: ...ow the table with cable and torque speci cationsbelow Terminal Block Connector Wire Size TQ Lb In Phoenix Contact Part No 1757022 14 20 AWG 2 08 0 52 mm2 5 7 Warning Do not open when an explosive atmo...

Page 6: ...ccompanyinginstallation instructions Onlyquali ed personnel may install the operatorpanel Separate the high voltage signal and supply cables Make sure that the voltage and polarity of the powersource...

Page 7: ...onment lithiumbattery electrolytic capacitorand display 1 8 Appearance of Air in Touch Screen The layerstructure of the touch screen contains airandinrare casesappearance of bubbles can arise This is...

Page 8: ...ce Requirements Maximum installation plate thickness 8 mm Space requirements in millimeterswhen installingthe operatorpanel 100 100 100 50 50 410 286 Note The dimensions on the drawing are not proport...

Page 9: ...rawingis available for download from the Beijer Electronics web site Formore information see sections Operator Panel Drawings and Technical Data 3 Secure the operator panel in position by screwingthe...

Page 10: ...from signal and supply cables Shielded communication cables are recommended 24V DC RS232 RS422 RS485 24V DC A D Controller Power B Ethernet C Use 14 20 AWG 2 08 0 52 mm2 wire forthe powerconnections C...

Page 11: ...chthem tostrain reliefplate with cable ties provided 2 2 3 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable forthe application and itsenvironment Forfurth...

Page 12: ...pin D sub contact with RS232 RTS CTS chassis mounted female with standard locking screws 4 40 UNC Communication module CAN Ethernet 1 x 10 100 1000 Base T shielded RJ45 1 10 100 Base T shielded RJ45...

Page 13: ...sistance for more information 2 Standby mode The backlight is turned off there are no cabled interfaces and the CPU is below 5 Optional CAN module is present 3 Typical mode The backlight is fully powe...

Page 14: ...chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Sodium hypochlorite Turpentine Note If exposure to any of...

Page 15: ...60 95 1 Bleach 1 Hydrochloric acid 36 Sulfuric acid 10 Castor oil Linseed oil Tomato ketchup Caustic soda 40 1 Methanol Trichloroaceticacid 50 Cutting oil Nitric acid 10 White Spirit Cyclohexanol Par...

Page 16: ...play protection lm thatcan be ordered from BeijerElectronics Outdoor Use In common with all polyesterbased lms Auto exEB is not suitable foruse in conditions oflong term exposure todirect sunlight Not...

Page 17: ...to the following chemicalsat room temperature Acetic acid conc Na hypochlorite 10 Ammonia 30 Nitric acid 10 Butanol Phosphoric acid 10 Ethyl acetate Phosphoric acid 20 Hydrochloric acid 37 cold Note...

Page 18: ...USB 2 USB Host 2 0 max output current 500 mA 5 Headphone Headphone Connector 6 LAN B 1 x 10 100 1000 Base T shielded RJ45 7 COM 2 RS422 RS485 Communication Port 5 2 Communication Ports Serial port 9 p...

Page 19: ...5 3 T15BR Outline 286 410 7 max 8mm 76 9 9 392 9 268 9 B C E D A E A Connectors B SD memory card slot C USB host D Expansionport E Optional CAN module not shown CAN depth doesnotexceed heatsink Beijer...

Page 20: ...cordingto localelectrical codes between the operatorpanel s quick connect plinth and the panel s chassis see 2 in drawing above 2 Connect awire orgroundingbraidthat is sized correctly accordingto loca...

Page 21: ...5 RJ45 RJ45 RJ45 Industrial Ethernet Operator panel Operator panel Operator panel Operator panel Shielded Short and unshielded 0 1 F 250 V 1 1 3 3 8 8 2 2 In some industrialunits forEthernet the RJ45...

Page 22: ...istobreak the shield see 3 in drawing above A more elegant methodistoexpand the shielded Ethernet cablingwith a piece of unshielded Ethernetcable see 4 in drawingabove The shield canbe grounded via a...

Page 23: ...shield to the ground via a 0 1 F 250 V plastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms ofLF thus avoidingthe 50 60 Hz gro...

Page 24: ...to heat The lifespan of an electrolytic capacitoris cut in halfwith an 8 10 C increase in temperature A 15 20 C temperature increase resultsin a quarter of the lifespanetc Rittal has a goodprogram for...

Page 25: ...Vaccording to EN 60950 protection against electric shock andUL 950 Example Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay co...

Page 26: ...al Many peripherals includingUSBdevices will bond the terminal s signal ground 0 V to the protective earth ground Bonding signal ground and protective earth ground mayincrease electricalemissions and...

Page 27: ...the ground potential the shield should be connected tothe ground via 0 1 F 250 V plastic capacitorto preventground current in the braided shield A numberof manufacturers recommendthat the shield be g...

Page 28: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...

Reviews: