background image

Settings in the programming tool

15

Beijer Electronics

2. Mark 

TCP/IP Connection 1 

and click 

Edit 

to make the settings for the 

TCP/IP network.

Summary of Contents for IFC ETCX

Page 1: ...IFC ETTP IFC ETCX Manual MA00328D 2001 12 English Svenska...

Page 2: ...ent works and its operation Beijer Electronics AB takes no responsibility if these examples are used in real applications Because of the great many areas for this equipment the user himself must acqui...

Page 3: ...ses below Name Company Address City Zip code Country Telephone Fax E mail Please fax this page to the Marketing Department Beijer Electronics AB at 46 40 93 23 01 or send it by conventional mail to Th...

Page 4: ...y before use The equipment should be operated by qualified personnel only At installation The product is constructed for stationary installation Install the product according to the accompanying insta...

Page 5: ...Safety precautions Beijer Electronics At disassembly and scrapping Local regulations apply concerning recycling of products or parts...

Page 6: ...tents 1 Installation 8 1 1 Installation of one expansion card 8 1 2 Installation of two expansion cards 10 1 3 The LEDs on IFC ETCX and IFC ETTP 11 2 Settings in the programming tool 12 2 1 Define slo...

Page 7: ...Contents Beijer Electronics...

Page 8: ...he manual for the terminals This chapter describes how to mount the expansion card in the terminal 1 1 Installation of one expansion card Perform the following steps to mount an IFC ETTP or IFC ETCX e...

Page 9: ...e expansion card placed upwards One of the expansion cables is mounted between X1 on the CPU card and X1 on the expansion card and the other cable between X2 on the CPU card and X2 on the expansion ca...

Page 10: ...for the expansion card placed in Slot 2 If only one card is used either connector can be used The connector X1 on the expansion card in Slot 2 is connected to the connector X1 and the CPU card in the...

Page 11: ...ollowing functions SEL YELLOW The LED is activated when the port on the expansion card is accessed from the processor in the terminal TxD YELLOW The LED is activated by Ethernet transmit activity RxD...

Page 12: ...rogramming tool Beijer Electronics 12 2 Settings in the programming tool Perform the following steps to use an Ethernet connection with IFC ETTP and IFC ETCX expansion cards 2 1 Define slot 1 Select S...

Page 13: ...3 Beijer Electronics 2 Select the slot defined with jumper J1 on the expansion card and click Edit 3 Select type of expansion card in this case IFC ETTP for connection via twisted pair cable or IFC ET...

Page 14: ...the settings for TCP IP in Peripheral configuration Drag the TCP IP Connection 1 icon from Unused functions to IFC ETTP or IFC ETCX on Slot 1 or Slot 2 The blinking arrows indicate where it is possib...

Page 15: ...Settings in the programming tool 15 Beijer Electronics 2 Mark TCP IP Connection 1 and click Edit to make the settings for the TCP IP network...

Page 16: ...terminal with one or several of the TCP IP parameters TCP IP Settings IP address and subnet mask State the node s network identity Connection in a network is made according to Ethernet standards For a...

Page 17: ...inals via pair twisted cable The maximum length between the terminals is 100 m The cable is a CAT5 pair twisted cable screened or not screened equipped with RJ45 connectors TCP IP settings in the node...

Page 18: ...wisted cable The maximum length between terminal and hub is 100 m The number of terminals per hub is limited by the number of connections to the hub The cable is a CAT5 pair twisted cable screened or...

Page 19: ...etwork will then comprise different segments The maximum length of a segment is 185 m with a maximum number of 30 units in each segment Four repeaters can be serial connected which means that five seg...

Page 20: ...services and Network accounts in the chapter Network communication in the manual for the operator terminals Note Settings for the expansion cards can also be made under Setup in the terminal Select s...

Page 21: ...Settings in the programming tool 21 Beijer Electronics...

Page 22: ...t elsen av utrustningens funktionalitet och handhavande Beijer Electronics AB tar inget ansvar om dessa exempel anv nds i verkliga applikationer P grund av det stora antalet anv ndningsomr den f r den...

Page 23: ...ligt nedanst ende adresser Namn F retag Adress Postadress Land Telefon Telefax E mail Faxa till Marknadsavdelningen Beijer Electronics AB 040 93 23 01 eller skicka med post till Marknadsavdelningen Be...

Page 24: ...anv ndarbeskrivningen noga innan produkten anv nds Utrustningen m ste hanteras av personal med adekvat utbildning Vid installation Produkten r konstruerad f r fasta installationer Installera produkten...

Page 25: ...S kerhetsf reskrifter Beijer Electronics Vid nedmontering och skrotning tervinning av produkten eller delar av produkten skall ske enligt g llande regler i respektive land...

Page 26: ...stallation 8 1 1 Installation av ett expansionskort 8 1 2 Installation av tv expansionskort 10 1 3 Lysdioderna p IFC ETCX och IFC ETTP 11 2 Inst llningar i programmeringsverktyget 12 2 1 Definiera kor...

Page 27: ...Inneh ll Beijer Electronics...

Page 28: ...sterminalerna Detta kapitel beskriver hur expansionskortet monteras i terminalen 1 1 Installation av ett expansionskort Montering av ett IFC ETTP eller IFC ETCX utf rs enligt f ljande steg 1 Sl av sp...

Page 29: ...upp t Den ena expansionskabeln monteras mellan X1 p CPU kortet och X1 p expansionskortet och den andra mellan X2 p CPU kortet och X2 p expansionskortet 6 Skruva fast kortet i terminalen med de medf l...

Page 30: ...tet som r placerat i kortplats 2 Om endast ett kort anv nds spelar det ingen roll vilken kontakt p kabeln som anv nds Kontakten X1 p expansionskortet i kortplats 2 kopplas till kontakten X1 p CPU kort...

Page 31: ...sdioderna har f ljande funktioner SEL GUL Lysdioden aktiveras n r terminalens processor har kontakt med por ten p expansionskortet TxD GUL Lysdioden aktiveras vid s ndning av Ethernet data RxD GUL Lys...

Page 32: ...get Beijer Electronics 12 2 Inst llningar i programmeringsverktyget F ljande steg utf rs f r att anv nda en Ethernet uppkoppling med expansions korten IFC ETTP eller IFC ETCX 2 1 Definiera kortplats 1...

Page 33: ...tronics 2 V lj den kortplats som angivits genom bygeln J1 p expansionkortet Klicka sedan p Redigera 3 V lj typ av expansionskort i det h r fallet IFC ETTP d partvinnad kabel anv nds vid anslutningen e...

Page 34: ...P g rs under Konfiguration av periferienheter Dra TCP IP Anslutning 1 med muspekaren fr n Oanv nda funktioner till IFC ETTP eller IFC ETCX p Kortplats 1 eller Kortplats 2 De blinkande pilarna visar vi...

Page 35: ...Inst llningar i programmeringsverktyget 15 Beijer Electronics 2 Markera TCP IP Anslutning 1och klicka p Redigera f r att g ra inst llningarna f r TCP IP n tverket...

Page 36: ...r tilldelar terminalen en eller flera av TCP IP parametrarna TCP IP inst llningar IP adress och subn tsmask Ange nodens n tverksidentitet Ethernet standard f r anslutning i n tverk till l mpas Till et...

Page 37: ...terminaler via partvinnad kabel Den maximala l ngden mellan terminalerna r 100 m Kabeln r en CAT5 par tvinnad kabel sk rmad eller osk rmad med RJ45 kontakter i ndarna TCP IP inst llningar i noderna O...

Page 38: ...rtvinnad kabel Den maximala l ngden mellan terminal och hub r 100 m Det maximala anta let terminaler per hub begr nsas av antalet anslutningar mot hubben Kabeln r en CAT5 partvinnad kabel sk rmad elle...

Page 39: ...rk N tverket best r d av olika segment Den maximala l ngden p ett segment r 185 m och maximalt 30 enheter kan anslutas per segment Fyra f rst rkare kan seriekopplas vilket inneb r att max imalt fem se...

Page 40: ...itten N tverkstj nster och N tverks konton i kapitlet N tverkskommunikation i manualen f r operat rsterminalerna OBS Inst llningar f r expansionskort kan ocks g ras under Setup i terminalen V lj kortp...

Page 41: ...Inst llningar i programmeringsverktyget 21 Beijer Electronics...

Reviews: