50
Software
Installation
|
To
Disabled
the
watchdog
timer,
simply
write
a
00H
to
the
watchdog
register.
;
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
;
Enter
the
extended
function
mode,
interruptible
double
‐
write
;
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Mov
dx,2eh
;
Enter
to
extended
function
mode
Mov
al,87h
Out
dx,al
Out
dx,al
;
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
‐‐‐‐‐‐‐‐
;
Logical
device
8,
configuration
register
CRF5
Bit
3(Sec./Min.),
CRF6
Bit
0~7
(Count.)
;
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
‐‐‐‐‐‐‐‐
Mov
al,07h
Out
dx,al
Mov
dx,2fh
Mov
al,08h
;
Select
Logical
Device
8
of
watchdog
timer
Out
dx,al
Mov
dX,2eh
Mov
al,0f5h
;Set
second
as
counting
unit
Out
dx,al
Mov
dx,2fh
In
al,dx
And
al,not
c8h
;Set
Second
or
Minute.
Out
dx,al
Mov
dx,2eh
Mov
al,0f6h
Out
dx,al
Mov
dx,2fh
Mov
al,00h
;
Set
Watchdog
Timer
Disabled
Out
dx,al
;
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
;
Exit
extended
function
mode
;
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Mov
dx,2eh
;Exit
the
extended
function
mode
Mov
al,0aah
Out
dx,al