background image

Foreword

Installation manual for T21C

Foreword

All operator panels are developed to satisfy the demands of human-machine
communication. Built-in functions such as displaying and controlling text,
dynamic indication, time channels, alarm and recipe handling are included.
The operator panel works primarily in an object-oriented way, making it easy to
understand and use. Configuration is carried out on a PC using the iX Developer.
The project can then be transferred and stored in the operator panel itself.
Various types of automation equipment such as PLCs, servos or drives can be
connected to the operator panels. In this manual, the term “the controller” refers
to the connected equipment.
This manual explains how to install the operator panel. Please refer to the
iX Developer reference manual for further information.

Order no: MAEN084E

Copyright © 2014-04 Beijer Electronics AB. All rights reserved.

The information in this document is subject to change without notice and is provided as available at the

time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any

information without updating this publication. Beijer Electronics AB, including all its group companies,

assumes no responsibility for any errors that may appear in this document. Read the entire installation

manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair

this equipment. Beijer Electronics AB, including all its group companies, are not responsible for modified,

altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire

the appropriate knowledge to use the equipment properly in their specific applications. Persons responsible

for the application and the equipment must themselves ensure that each application is in compliance with

all relevant requirements, standards and legislation in respect to configuration and safety. Only parts and

accessories manufactured according to specifications set by Beijer Electronics AB, including all its group

companies, may be used.

BEIJER ELECTRONICS AB, INCLUDING ALL ITS GROUP
COMPANIES, SHALL NOT BE LIABLE TO ANYONE FOR ANY
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE INSTALLATION, USE OR
REPAIR OF THIS EQUIPMENT, WHETHER ARISING IN TORT,
CONTRACT, OR OTHERWISE. BUYER'S SOLE REMEDY SHALL
BE THE REPAIR, REPLACEMENT, OR REFUND OF PURCHASE
PRICE, AND THE CHOICE OF THE APPLICABLE REMEDY SHALL
BE AT THE SOLE DISCRETION OF BEIJER ELECTRONICS AB,
INCLUDING ALL ITS GROUP COMPANIES.

Beijer Electronics, MAEN084E

Summary of Contents for T21C

Page 1: ...T21C Installation Manual English MAEN084E 2014 04...

Page 2: ...roup companies assumes no responsibility for any errors that may appear in this document Read the entire installation manual prior to installing and using this equipment Only quali ed personnel may in...

Page 3: ...pactFlash or CFast Memory Card 14 3 4 Replacing the Battery 15 4 TechnicalData 16 5 ChemicalResistance 18 5 1 MetalCasing 18 5 2 Touch Screen and Overlay 19 5 2 1 Autotex F157 207 19 5 2 2 Touch Scree...

Page 4: ...r In case of eye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserves an illustrative purpose Because of the many variables associated with any pa...

Page 5: ...rgent Replacingthe battery incorrectly mayresultin explosion Only use batteries recommended by the supplier Duringthe warrantyperiod the batteryneeds tobe replaced byan authorized Beijer Electronics s...

Page 6: ...mm Space requirements in millimeterswhen installingthe operatorpanel 556 mm 347 mm 50 mm 100 mm 50 mm 100 mm 100 mm Note The dimensions on the drawing are not proportional Caution The openings on the...

Page 7: ...allmay cause damage 2 Tocuta correct opening forthe operatorpanel use the cut out dimensions in the outline drawing Aseparate cut out drawingis available for download from the Beijer Electronics web s...

Page 8: ...n may occur Ensure that the voltage and polarity of the powersource is correct Separate high voltage cables from signal and supply cables Shielded communication cables are recommended 24V DC RS232 RS4...

Page 9: ...rator panelto the controller please refer to the help le for the driverin question 2 2 2 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable forthe applicati...

Page 10: ...landspare partslist are allowed 3 1 Replacing the Fan and Filter The followingis needed A newfan A Torx TX10 and a TX20 screwdriver Note Make sure to use adequate ESD protection Follow the steps below...

Page 11: ...e Replacement 4 Remove the fanby removingthe two M4x35 Torx screws 5 Reassemble with new fan and lterin reverse order Use a maximum torque of 0 4 Nm whenfastening the fanscrews Beijer Electronics MAEN...

Page 12: ...mbly it is important to take care of the cable between the front and the rear part If you disconnect a cable be sure that the right cable will be in the right position when assembling Note The exchang...

Page 13: ...5 Remove the hard disk drive from the hard drive connection onthe CPU board 6 Reassemble with the newhard disk drive inreverse order 1 2 5 SATA mass storage 2 CompactFlash slot 3 CFast slot Beijer Ele...

Page 14: ...SD protection Follow the steps belowtoreplace amemory card 1 Power off the operator panel 2 Followthe instructions in chapter Replacingthe 2 5 SATA Mass Storage to remove the front frame assembly 3 In...

Page 15: ...driver Note Make sure to use adequate ESD protection Follow the steps belowtoreplace the battery 1 Power off the operator panel 2 Followthe instructions in chapter Replacingthe FanandFilter toremove t...

Page 16: ...0 UNC Note RS422 Interface is not available yet Serial port for COM3 RS232 and COM4 RS422 RS485 9 pin D sub contact with RS232 RTS CTS chassis mounted female with standard locking screws 4 40 UNC Note...

Page 17: ...backlight 1920 1080 pixels 16 7 million colors VGA 1 VGA resolution max 2048 1536 75Hz DVI 1 DVI D single Link Resolution max 1600 1200 or 1920 1200 with reduced blanking Active area of display W H 47...

Page 18: ...hemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Sodium hypochlorite Turpentine Note If exposure to any of...

Page 19: ...ution 1 Gumption 1 SBP 60 95 1 Bleach 1 Hydrochloric acid 36 Sulfuric acid 10 Castor oil Linseed oil Tomato ketchup Caustic soda 40 1 Methanol Trichloroaceticacid 50 Cutting oil Nitric acid 10 White S...

Page 20: ...rotection lm that can be ordered from Beijer Electronics Outdoor Use In common with all polyesterbased lms Auto exEBA 180L is not suitable for use in conditions of long term exposure todirect sunlight...

Page 21: ...Host 2 0 maxoutputcurrent 500 mA 8 USB 2 USB Host 2 0 maxoutputcurrent 500 mA 9 Power supply DC inputrange 18 32 V DC 140 W ATX standard 6 2 Communication Ports Serial port 9 pin female Serial port 9...

Page 22: ...to utilize two communication ports on the same physical port the Y split cable CAB109 must be used Drawing for external cable CAB109 drawing Z7100 029E is available on the web site www beijerelectroni...

Page 23: ...Operator PanelDrawings 6 3 T21C Outline max 8 mm 8 79 329 9 9 347 9 9 537 556 Beijer Electronics MAEN084E 23...

Page 24: ...Operator PanelDrawings Note A Step CAD file is available on the web site www beijerelectronics com Beijer Electronics MAEN084E 24...

Page 25: ...cordingto localelectrical codes between the operatorpanel s quick connect plinth and the panel s chassis see 2 in drawing above 2 Connect awire orgroundingbraidthat is sized correctly accordingto loca...

Page 26: ...RJ45 RJ45 RJ45 Industrial Ethernet Operator panel Operator panel Operator panel Operator panel Shielded Short and unshielded 0 1 F 250 V 1 1 3 3 8 8 2 2 In some industrialunits forEthernet the RJ45 c...

Page 27: ...istobreak the shield see 3 in drawing above A more elegant methodistoexpand the shielded Ethernet cablingwith a piece of unshielded Ethernetcable see 4 in drawingabove The shield canbe grounded via an...

Page 28: ...shield to the ground via a 0 1 F 250 V plastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms ofLF thus avoidingthe 50 60 Hz gro...

Page 29: ...to heat The lifespan of an electrolytic capacitoris cut in halfwith an 8 10 C increase in temperature A 15 20 C temperature increase resultsin a quarter of the lifespanetc Rittal has a goodprogram for...

Page 30: ...Vaccording to EN 60950 protection against electric shock andUL 950 Example Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay co...

Page 31: ...hield mustbe grounded at one end The other end is usuallygrounded but with longerdistances or whenthere is adifference in the ground potential the shield should be connected tothe ground via 0 1 F 250...

Page 32: ...ces like for example serial devices 1 Connect aUSBKeyboard 2 Connect power supply and turn onthe operator panel 3 While booting press the F2 key immediately afterthe keyboard isinitialized The initial...

Page 33: ...lationTips 7 9 Reset Switch A resetswitch is locatedunder the fan lid Follow the instructionsin chapterReplacing the Fanand Filter on how toremove the fan lid to accessthe reset switch Beijer Electron...

Page 34: ...Head office Beijer Electronics AB Box 426 201 24 Malm Sweden www beijerelectronics com 46 40 358600...

Reviews: