Appendix
Ⅰ
Parameter Setting List
Number
Name
Recommended
Value
Range of Setting
Note
C34
Sequin Off
after T.B.
No
No, Yes
It is used to control the position
of the sequin device after the
thread-breakage.
C56
Sequin Ind.
UpDown
No
No, Yes
B17
Up Valve
When Jump &
Nocut
Yes
No, Yes
D70
R Motor Shift
Stroke Base
40
6
~
40
D71
R Motor Shift
Stroke Time
15
1
~
30
D72
With Origin at
R Motor Shift
Yes
D83
R Knife Start
Angle Adj
15
0
~
31
D73
L Sequin
Feeding Angle
Ad
40
6
~
40
D74
L Motor Shift
Stroke Time
15
1
~
30
D75
With Origin at
L Motor Shift
Yes
D84
L Knife Start
Angle Adj
15
0
~
31
D99
Bead-breakage
Detection
Sensitivity
0
0
~
10
D54
Motor Number
of R Sequin
No,1~4,1(2~4)
Set the parameter base on sequin
device. 2~4 mean the number of
sequin device driven by one
motor
D55
Set 3MM of R
Sequin
Single-way 6~40 steps;
Dual-way 6~40 steps
D56
Set 4MM of R
Sequin
Single-way 6~40 steps;
Dual-way 6~40 steps
D57
Set 5MM of R
Sequin
Single-way 6~40 steps;
Dual-way 6~40 steps
D58
Set 6.75MM of
R Sequin
Single-way 6~40 steps;
Dual-way 6~40 steps
154 BECS- D56 computerized embroidery machine owner’s manual
Summary of Contents for BECS-D56
Page 2: ......