VISTA DIGITAL INKJET PRINTER MANUAL
Beijing Innovation Technology Co.,Ltd. PAGE 60
www.jhfvista.com
TEL
:
86 10 62950101 FAX
:
86 10 82410746
Movement system setting
Item
purpose
Remark
X reposition
speed
The speed of the carriage return to the original
slow/middle/fast the carriage speed while printing
X movement
Click movement, the carriage move, the raster
transfer the signal, click calculate, the system will
account the step parameter automatically.
Y movement
Click movement, the stepping driver move,
measure the moved distance. Input the parameter
you measured, the system will account the
stepping parameter automatically.
6.4. Fiber Installation:
B
A
B
A
Two fibers A & B used for connect the control card of the print head and PCI card, as there is connect
port of fiber for each control card. There is Tx and Rx stick on the port. While one end of the fiber
plug into Tx, then the other one should plug into Rx. Please kindly notice that you should point to the
right port.
Attentions: the fiber shouldn’t be curved or tied less than 90 degree. Otherwise, the
光纤
may
be damaged in the retrieval condition. Even lead to its disability to transfer the data directly. If you
want to change the point of the fiber, then 3cm Turning radius should be kept.