background image

6

Description

1

Holder neck

2

Ventilation windows

3

RF Micro needle hand piece connecter

4

Grounding bar connecter.

5

RF fractional hand piece connecter

6

Power code connecter.

7

Foot switch connector

3

4

5

6

7

Summary of Contents for PINXEL

Page 1: ...bility for its use In any of case specifications are subject to change without notice CONVENTIONS Used in this Manual The following conventions in the form of notes cautions and warnings are used in this manual Note The content of this Note offers general information that is important to keep in mind Caution A Caution alerts the user to the possibility of a problem with the device associated with ...

Page 2: ...or misuse of the system Table Table o of f Contents Contents 1 Before Use A Notice B Symbols Label 2 System Features 3 System Composition 4 Description of Product A Main Unit B Main Unit Rear C Hand piece 5 Operating Instruction A Preparations B Safety checking before operation C Operation procedure D Error message 6 Specification A System classification B Electrical specification C Mechanical spe...

Page 3: ... technical works by our instruction B Symbols Label Warning Alert Label for potential risks in usage of laser devices will be adhered on Main body 2 System Features Pinxel Fracitonal RF Technology allows effectively treatment of deeper dermis epidermis and upper dermis RF energy is emitted at the end of fractional RF micro needle this will treat target area deeper dermis without damage of epidermi...

Page 4: ... b Available to treat both epidermis and dermis layers c It is suitable for all skin types d Lesser risk of PIH and side effects e RF Fractional and RF micro needle technologies are in one platform 3 System Composition Front view 2 4 1 2 3 4 5 6 7 8 9 ...

Page 5: ...Description 1 LED Screen 2 Key Switch 3 Emergency off Button 4 Main unit 5 RF fractional hand piece 6 Earth grounding bar 7 RF micro needle hand piece 8 Holder for hand pieces 9 Holder screw Back view 1 2 ...

Page 6: ...escription 1 Holder neck 2 Ventilation windows 3 RF Micro needle hand piece connecter 4 Grounding bar connecter 5 RF fractional hand piece connecter 6 Power code connecter 7 Foot switch connector 3 4 5 6 7 ...

Page 7: ...7 System Composition RF fractional hand piece RF micro needle hand piece Grounding bar Foot switch Power cord 4 Control Panel 1 2 3 ...

Page 8: ...u operate it on patients B Safety check before operation 1 Renew the patient s treatment record 2 Check if all operation materials including micro needle kit are sterilized in normal condition 3 To start operation procedure we recommend that you check if each modes works properly before you apply it on patient in order to prevent unexpected abnormalities 4 Establish proper parameter considering pa...

Page 9: ...ody 2 Turn power on position then power switch on front side of main unit will be activated 3 Make sure grounding bar and foot switch are properly connected 4 Initial screen will be displayed as following upon key switch on and stand by screen will be shown after 2 3 seconds Initial Screen Micro Needl RF Mode 5 Select micro needle RF mode and then you can find screen like below picture ...

Page 10: ...time between first shot and next shot Single 0 5 1 0 1 5 2 0 2 5 3 0 sec 4 Active pulse To set continuance of output time per each shot 10 300 msec 5 Depth To set the depth of penetration of micro needle 0 5 3 0mm 6 Shot count To count out put on each mode 7 Back To return to initial screen 8 Standby Ready To select standby and ready mode Fractional RF Mode No Items Descriptions 1 Intensity To det...

Page 11: ... and off the system Please be noted that it is not completely power off during stand by status It will be completely power off by pressing main power switch in rear side of main unit 6 Specification A System Classification 1 Electric shock protection Class I equipment 2 Electrical device class by IEC Class IIa 3 Protection against ingress of liquids Ordinary equipment 4 Mode of operation Stand by ...

Page 12: ...ironment and Restrictions for use 1 Environment Do not use where humidity is high example bathroom 1 Operating Temperature 10 C 40 C With enclosure 2 Operating Humidity 10 80 Non condensing 3 Storage Temperature 10 C 60 C With enclosure 4 Storage Humidity 10 90 Non condensing 5 Pressure 500 1060 hPa B Cautions before use 1 Check operation procedure preliminary 2 Check buttons to make sure they wor...

Page 13: ...ical specialist 6 Pay attention to following cautions during use 1 Check whether there are abnormal conditions in the equipment or patient 2 If any abnormal condition in the equipment or patient is found take care of patient first 3 Then stop using the equipment Start reusing after checking patient and the equipment 4 Not qualified persons including patient are not allowed to contact the equipment...

Page 14: ...e the foreign substance like cosmetics The patient must wear the protective goggles Begin the energy for treatment from low power to prevent any side effect and lower the patient s treatment expectancy level and it will be better to perform the operation with frequent treatments B Treatment procedure 1 wear anesthesia cream on the treatment area Anesthesia is suitable for about 45 55 minute After ...

Page 15: ... other half of face also it is very important that all the patients should cooling the face completely after treatment We recommend you to use cooling up to 40 to 60 minute continuously by roller or Ice pack etc Cooling is very important to prevent any side effect and when patient face still feel hot after cooling then please cooling their face by using fan or air conditioner blow cooling air to t...

Page 16: ... This is a multiple treatment and it can improve the skin property all round 4 Is it suitable for sensitive skin The sensitive skin is suitable for the Fractional RF treatment it could change the sensitivity in some degree 5 Is it suitable for the dark color skin It is suitable for the dark color skin since there is not light power only RF energy The dark skin could use the treatment 6 Does the sk...

Page 17: ...treatment could keep 2 6 month 3 10 years can kept after one whole course 9 Contact Details Company Beijing Sanhe Beauty S T Co Ltd Adds 3rd floor 6E Building Liando U Valley Tongzhou District Beijing China Tel 8610 81597649 81596921 Web http www sanhebeauty com Email Gxl sanhebeauty com ...