Chapter 3 Installation and test 

1.Make sure the E1-link cables are compatible with the RC901-FE4E1

 

If the E1 links with which you want to connect RC901-FE4E1 are combined with 
PDH or SDH equipments, please check the interface type of E1, definition and 
impedance of interface in relevant manuals. 

 

2. Choose proper E1 link cables   

Balanced:        0.6mm(22AWG) twisted pairs, up to 1500m 

 

3.BALANCE-RJ45 UTP E1 pin defined as shown below 

Refer to the table and figure below when use the balanced interface (120 

PIN 

No.  1  2 3 4 5 6 7 8 

Label TD+ 

TD- 

Not 

used 

Not 

used 

RD+ RD-  Not 

used 

Not 

used 

Signification  Output- 

  

Input+ Input-

  

120

 balanced interface connect with other equipment, need specify the pin of the 

equipment. The connection of UTP pin is shown below. 

 

RC BALANCE-RJ45  

       E1 balanced interface 

TD

   

 

 

 

 

 

 

TD

   

 

 

 

 

 

Output- 

RD

 

      Input+ 

RD

 

      Input

 

Note:

        TD

 and  TD

  are always in one twisted pairs 

                  RD

 and  RD

  are always in one twisted pairs 

 

4. Environment   

Temp: 0-45

 

Humidity: 5%~90% no condensing   
 

5. Power supply 

 

AC: 220v/50Hz Voltage 165~265V 
DC: 

48v Voltage 

36~ 

72V  

Power consumption 

 3W 

 
 
 

 

 
 

 

7

Summary of Contents for RC902-FE4E1

Page 1: ...RC902 FE4E1 fast Ethernet to 4 E1converter User guide Beijing Raisecom Science Technology Co ltd...

Page 2: ...Content Chapter 1 Overview 3 Chapter 2 Connection features 6 Chapter 3 Installation and test 7 Chapter 4 Introduction of DIP Switch 8 Chapter 5 Troubleshooting 12 2...

Page 3: ...3 Other features Real time BER detecting and E1links auto protection auto reset Resistance for drift of 512UI the ability of counteraction of jitter and drift Selectable BER threshold of link auto res...

Page 4: ...king means the two converters have no alarm occurs in E1 link 3 Fault Pass Through RC901 FE4E1 provides Fault Pass Through FPT for special requirements e g which need Spanning Tree superior switch net...

Page 5: ...If A link has been connected A link is green Other link indicators are off Then B link is connected B link is green automatically Green means that normal status And so on A B C D four E1 links are all...

Page 6: ...Switch and NIC can be connected by both straight line and cross line If UTP port is set to define fixed speed or Full duplex mode RC901 FE4E1 will lose this function The feature of that RC902 FE4E1 co...

Page 7: ...er to the table and figure below when use the balanced interface 120 PIN No 1 2 3 4 5 6 7 8 Label TD TD Not used Not used RD RD Not used Not used Signification Output Output Input Input 120 balanced i...

Page 8: ...more than 10 6 4bit choice of compatibility 5bit reserved 6bit configuration of Eth 7bit configuration of Eth Shown as table and figure below 8bit fault pass Disable Enable Remote loopback If any of E...

Page 9: ...interface Sniffer is for diagnosing Ethernet interface Note Ethernet data also loop back during local loop back it easy to make broadcast storm which occurred in Ethernet switches connected with loca...

Page 10: ...le auto sensing function force port to 10M half duplex 10M half duplex will be obtained 10M Full duplex port Disable auto sensing function force port to 10M full duplex 10M full duplex will be obtaine...

Page 11: ...function for special requirements In case of any E1 link was out of work RC901 FE4E1 could transmit the Ethernet packets in the other available E1 links automatically until all E1 links were not avai...

Page 12: ...rd Please check the fault pass function is Enable or Disable If it is Enable it can make Ethernet port to close 3 E1 line indicator alarm If there is E1 line alarm please find the fault reason accordi...

Reviews: