background image

Normaly  open  solenoid  valve  12VDC

ATTENTION  !
Relay  is  voltage  free

The  power  supply  is  2307240  VAC.  with  a  buffer
battery  12VDC  1.2Ah  MAX

Electrical  Connections

ATTENTION  !
Relay  is  voltage  free

The  power  supply  is  230/240  VAC.  with  a  buffer
battery  12VDC  -  1.2Ah  MAX
N.B.  The  12VDC  voltage  can  be  derived  from
another  source.

Normaly  open  solenoid  valve  12VDC

N C

C

NO

+

1    2    3    4    5     6    7

Solenoid  valve  NA  12  VDC

Connection  with  a  normally  closed  solenoid  valve 

 

12  VDC

N C

C

NO

N

Ph

+

1    2    3    4    5     6    7

230/240  VAC

Solenoid  valve  NA  12  VDC

ATTENTION  !
Relay  is  voltage  free

The  power  supply  is  230/240  VAC.  with  a  buffer
battery  12VDC  1.2Ah  MAX

N C

C

NO

+

1    2    3    4    5     6    7

N

Ph

Solenoid  valve  NC  12  VDC

Page  5

Summary of Contents for RGX100

Page 1: ...ith the concept of home fitness comes the household gas detector RGX100 detects through the catalytic sensor the presence of explosive gas such as Methane LPG Gas detection The detector is tested and calibrated to 10 of L E L The power supply unit allows driving of a manual reset solenoid valve with a 12Vdc coil without any buffer battery If the voltage absorption is too high you can later integra...

Page 2: ...a specialized technician The disposal of the detector 5 years after installation It must be carried out by qualified technician Mains power 230VAC 50 60 Hz 10 Battery power 12 VDC 1 2 Ah 10 Current consumption 3 1 W 230V Range of relay contact switching 10A 250V resistive 5A 30Vdc resistive Battery charger Max Built in for a 1 2Ah 12VDC battery Insulation Class II Explosive gas sensor Catalytic Ex...

Page 3: ...ds and then will reopen them This is needed to prevent damaging some types of manual reset solenoid valve coils This features is suitable only when a 12 Vdc electrovalve is connected By opening the two poles the relay will be set to continuous functioning 6 Relay This relay changes its position when the detector trigger the main alarm 7 Catalytic sensor for Methane or LPG explosive gas detection 8...

Page 4: ...e free Power supply 230 240 VAC Electrical connections WARNING Before connecting to the mains power ensure the voltage is correct Carefully follow the instructions and the connections according to Regulations in force An automatic disconnetting switch appropriately identified as the detector sectioning device must be incorporated in the electrical system suitably located and easily accessible N C ...

Page 5: ...tery 12VDC 1 2Ah MAX N B The 12VDC voltage can be derived from another source Normaly open solenoid valve 12VDC N C C NO 1 2 3 4 5 6 7 Solenoid valve NA 12 VDC Connection with a normally closed solenoid valve 12 VDC N C C NO N Ph 1 2 3 4 5 6 7 230 240 VAC Solenoid valve NA 12 VDC ATTENTION Relay is voltage free The power supply is 230 240 VAC with a buffer battery 12VDC 1 2Ah MAX N C C NO 1 2 3 4 ...

Page 6: ...r should not be installed in environments where the temperature drops below 10 C or rises above 40 C The detector is equipped to detect different types of gases and according to these its must to be positioned at different heights These heights are 30 cm from the lowest point of the floor in order to detect heavy gases LPG etc 30 cm from the highest point of the ceiling in order to detect light ga...

Page 7: ...oes into alarm and closes the connected equipment Check that connections are correct and that the jumper which leads to the common voltage of the relay has been carried out all the relays are voltage free Check the scheme of connection If RGX100 is connected to a Solenoid valves 12 VDC and does not work To RGX100 you can not connect directly solenoid valves sirens in 12 VDC It must always to use t...

Page 8: ...excluded from the warranty BEINAT S r l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collec...

Reviews: