background image

BE-Rev  4  17  25

Serial  Number

Stamp  and  signature  of  the  dealee

Sensor 

SG800

Purchase  date

Lo  styling  è  della    b  &  b  design

In agreement with its continuous development policy, we reserve the right to modify its products without notice.

Made in Italy

 IP66

Business  -  info@beinat.com
Help  Desk  -  laboratorio@beinat.com

BEINAT    S.r.l.    Via  Fatebenefratelli  122/C
10077,  S.  Maurizio  C/se  (TO)  -  ITALY
Tel.  011.921.04.84  -  Fax  011.921.14.77
http://  www.beinat.com

INSURANCE.  This  device  is  insured  by  the  SOCIETÀ  REALE  MUTUA  for  the  PRODUCT'S  GENERAL  LIABILITY
up to a maximum of 1,500,000.00 EURO against damages caused by the device in case of failures in functioning.

WARRANTY.  The  warranty  term  is  3  years  from  manufacturing  date,  in  agreement  with  the  following
conditions.  The  components  acknowledged  as  faulty  will  be  replaced  free  of  charge,  excluding  the  replacement
of  plastic  or  aluminium  cases,  bags,  packing,  batteries  and  technical  reports.
The  device  must  arrive  free  of  shipment  charges  to  BEINAT  S.r.l.
Defects  caused  by  unauthorized  personnel  tampering,  incorrect  installation  and  negligence  resulting  from
phenomena  outside  normal  functioning  shall  be  excluded  from  the  warranty.
BEINAT S.r.l.  is  not  liable  for  possible  damage,  direct  or  indirect,  to  people,  animals,  or  things;  from  product
faults  and  from  its  enforced  suspension  of  use.

DISPOSAL OF OLD ELECTRICAL & ELECTRONIC EQUIPMENT.
This  symbol  on  the  product  or  its  packaging  to  indicates  that  this  product  shall  not  be  treated  as  household  waste.  Instead,
it  shall  be  handed  over  to  the  applicable  collection  point  for  the  recycling  of  electrical  and  electronic  equipment,  such  as  for
example:
-  sales  points,  in  case  you  buy  a  new  and  similar  product
-  local  collection  points  (waste  collection  center,  local  recycling  center,  etc...).
By  ensuring  this  product  is  disposed  of  correctly,  you  will  help  prevent  potential  negative  consequence  for  the  environment
and human  health,  which could otherwise be caused  by  inappropriate  waste handing of this product.  The recycling of materials
will  help to  conserve natural resources. For more  detailed information  about  recycling of  this  product, please  contact your local
city  office,  your  household  waste  disposal  service  or  the  shop  where  you  purchased  the  product.
Attention:  in some countries  of  the European Union, the  product  is not included  in  the field  of  application of the  National Law
that  applies  the  European  Directive  2002/96/EC  and  therefore  these  countries  have  no  obligation  to  carry  out  a  separate
collection  at  the  “end of  life”  of  the  product.

Summary of Contents for SG800

Page 1: ...plosive gas such as Methane LPG Hydrogen Freon Chlorine Idrogen Sulphide OXYGEN and other type of gas The probe has two danger levels 1st LEVEL pre alarm This was set at see Table on page 2 2nd LEVEL main alarm This was set at see Table on page 2 For Oxygen ALARM for Oxygen deficiency and Oxygen Excess The probe is managed by a microprocessor which not only supplies an alarm signal to the control ...

Page 2: ...follow the drawing closely Any use of the detector for purposes other than the intended one is considered improper and as a result of which BEINAT S r l therefore disclaims any responsibility for possible damages caused to people animals or objects TERMS and EXPECTATIONS The installation of the SG800 Probe its ordinary and extraordinary maintenance every six months and its out of service removal a...

Page 3: ...Box unit 2 zones Wall 16 I P 6 5 1 2 Y E S Y E S TAKITJ8 Data Collector Wall 8 I P 6 5 Compatible control units The installation of the detector is not exempt from The compliance with all regulations concerning the characteristics installation and use of gas appliances The ventilation of the spaces and the elimination of combustion products are described in the UNI norms according to ART 3 LAW 108...

Page 4: ... not be placed near the appliances to be controlled boilers burners industrial kitchens etc but on the opposite wall The probe should not be affected by smoke vapour etc as they could distort their measurement It must be placed away from sources of heat suction fans ventilation fans Positioning of the Probe Page 4 Detection Diagrams Data NO NO 30 cm Light Gases Light medium gas volatile 30 cm Heav...

Page 5: ...arefully follow the instructions and the connections according to Regulations in force keeping in mind that the signal cables should be laid separate from the power cables Electrical connections All relays are voltage free Contact capacity 10A 48VDC resistive SELV C NC NO C NC NO C NC NO 10 9 8 7 6 5 4 3 2 1 Linear output 4 20 mA Powersupply 12 24 V General alarm relay Fault relay Pre alarm relay ...

Page 6: ...1 Vdc If other problems arise the Distributor of BEINAT S r l should be contacted directly Troubleshooting before calling a technician Description and connecting probe SG800 Freon OXYGEN Led ON USB data NC C General Alarm R 5 4 3 2 1 Power supply 12 24 V Linear output 4 20 mA The relay is voltage free Contact capacity 1A 48VDC SELV USB data OXYGEN FREON Linear Otput 4 20 mA 3 2 1 R 0 1 3 2 1 1 VDC...

Page 7: ... all free flames 2 Close the main gas tap or the LPG cylinder tap 3 Do not turn any lights on or off do not turn on any electrical device or appliance 4 Open windows and doors in order to increase ventilation If the alarm stops its cause must be found and the relevant consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and ...

Page 8: ...anty BEINAT S r l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the rec...

Reviews: