23
6.5.7
Lower display:
di5P-2
The configuration of the lower display which has six
12mm high digits, depend upon whether the repeat
timer function
CYCLE5
, which can repeat the timing
period up to 99 times or continuously with a
configurable delay between periods, is enabled.
The configuration options are:
CYCLE5
disabled
The lower display shows the set time
5ET t
or the lower display may be disabled.
CYCLE5
enabled
The lower display shows the total number of
repeat cycles requested together with the
current
cycle
number.
During
the
configurable delay between cycles the
display times-down from the requested
delay time to zero. Each operation may be
briefly named at it's start or periodically
throughout the cycle.
The lower display may also be disabled if
not required.
To check or change the configuration of the lower
display select
di5P-2
from the configuration menu
and press
(
which will reveal the existing setting
which can be changed by pressing the
*
or
&
button followed by the
)
button to enter the
selection and return to the configuration menu.
If the
CYCLE5
function is not enabled the
following two options are available:
5td
Lower display shows the Timer's set
time
5Et t
, from which the BA377NE
will time-up or time-down depending
upon the direction of count selected in
the
uP or dn
function.
oFF
Lower display disabled.
If the
CYCLE5
function is enabled the following
three options are available:
5td
Lower display shows the number of
cycles requested together with the
current cycle number.
During the
configurable delay period the display
times-down from the requested delay to
zero. A brief notification of timer status
i.e.
CYCLE
or
dELAY
is shown at start of
each period.
02 - 11
Current
Number of cycles
cycle
requested, not shown
number
when cycle is
continuously repeated.
LabEL
Exactly the same as
5td
, but timer
status i.e.
CYCLE
or
dELAY
is shown
periodically.
oFF
Lower display disabled.
6.5.8
Starting & stopping the Timer:
5tAr5toP
The Timer may be started and stopped by a sensor
input signal or by operation of the front panel
*
or
&
push buttons.
To check or change the control of the Timer, select
5tAr5toP
from the configuration menu and press
(
which will reveal the existing setting which can be
changed by pressing the
*
or
&
button followed
by the
)
button to enter the selection and return to
the configuration menu. Options available are:
Voltage inputs or control from front panel
Display
Start
Stop
ControL 1
Input high
Input low
ControL 2
Input low
Input high
LoCAL
&
button
*
button
Contact and open collector inputs
Display
Start
Stop
ControL 1
Open
Closed
ControL 2
Closed
Open
Proximity detector input
Display
Start
Stop
ControL 1
Low current
High current
ControL 2
High current
Low current
6.5.9
Units of display:
unit5
Defines the format of all displayed times, except the
delay time of the optional control outputs which is
shown in seconds and the grand total which is
shown in hours and tenths of an hour.
To check or change the units of display, select
unit5
from the configuration menu and press
(
which
will reveal the existing setting. The required units
can be selected by pressing the
*
or
&
button
followed by the
)
button to enter the selection and
return to the configuration menu.
The options
available are shown below:
Display
12 : 00 : 00
Hours, minutes & seconds
12 : 00
Hours & minutes
*
30 : 00
Minutes & seconds
30
Seconds
*
Only available when time in seconds specified in
any Timer function is zero or divisible by 60.
The Timer's maximum elapsed time in any format is
equivalent to 99 hours, 59 minutes & 59 seconds.