Using the
&
or
*
push button change
Clr no
to
clr ye5,
pressing
(
will result in the instrument
displaying
0000
with the first digit flashing. This is a
request to confirm the reset instruction by entering
5urE
. Using the
&
or
*
button set the first flashing
digit to
5
and press
(
to transfer control to the
second digit which should be set to
u
. When
5urE
has been entered pressing the
)
button will reset
the grand total which will be confirmed by a brief
display of
Gt Clrd
, the instrument will automatically
return to the
Clr Gt
prompt in the configuration menu.
Note:
Once reset, the grand total can not be
recovered.
5.27 Security code:
CodE
Access to the instrument configuration menu may be
protected by a four digit security code which must be
entered to gain access. New instruments are
configured with the default security code 0000 which
allows unrestricted access to all configuration
functions.
To enter a new security code select
CodE
from the
configuration menu and press
(
which will cause the
BA564G Counter to display
0000
with one digit
flashing. The flashing digit may be adjusted using the
&
and
*
push buttons, when set as required
operating the
(
button will transfer control to the
next digit. When all the digits have been adjusted
press
)
to return to the
CodE
prompt. The revised
security code will be activated when the BA564G
Counter is returned to the display mode.
Please contact BEKA associates sales department if
the security code is lost.
5.28 Reset configuration to factory defaults
r5Et dEF
This function returns the BA564G Counter to the
factory defaults shown in section 5.0. To prevent
accidental use the request must be confirmed by
entering
5urE
before the configuration change will
be executed.
Select
r5Et dEF
from the configuration menu and
press
(
.
the instrument will display
0000
with the
first digit flashing. To confirm the instruction to
reset all the configuration functions to factory
defaults
5urE
must be entered. Using the
&
or
*
button set the first flashing digit to
5
and press
(
to transfer control to the second digit which
should be set to
u
. When
5urE
has been entered
pressing the
)
button will reset all the
configuration functions to the factory default
settings and zero both the total display and the
grand total. While resetting the BA564G Counter
will display
- - - - - - - -
before automatically
returning to the display mode when the operation is
complete.
5.29 Display overflow
The BA564G Counter total has a maximum display
range of -9999999 to 99999999 when shown on
the eight digit upper display. If this range is
exceeded the display will be as shown below with
all of the decimal points flashing:
Overrange
9.9.9.9.9.9.9.9
Underrange
-9.9.9.9.9.9.9
When the total is shown on the lower six digit
display the maximum display range is
-99999
to
999999
.
When a total overflow occurs the actual total may
be obtained from the instrument's grand total
display which has sixteen digits - see 2.2.
To prevent future total display overflows occurring
the total scale factor
5CALE
.
t
and the position of
the decimal point in the total display
dP
should be
reviewed.