6.3 Access Pulse output sub-menu:
PuL5E oP
Using the
&
or
*
push button scroll through the
Counters configuration menu until
PuL5E
.
oP
is
displayed, pressing
(
will then access the pulse
output sub-menu which is shown in Fig 10.
Fig 10 Pulse output configuration sub-menu
6.4 Enable pulse output:
EnbL
This function allows the pulse output to be disabled or
enabled without altering any of the pulse output
parameters. Using the
&
or
*
push button select
EnbL
in the pulse output sub-menu and press
(
. to
reveal the existing setting
on
or
oFF
. The function can
be changed by pressing the
&
or
*
push button
followed by the
)
button to return to
EnbL
prompt.
6.5 Source of output pulse:
5ourCE
The output pulse may be derived from:
dirECt A
Output is duplicate of input A
pulse.
dirECt b
Output is duplicate of input b
pulse.
5CALEd
Output is derived from the total
display and is only functional when
the
Count
function is configured for
A
+
b
. When
5CALEd
is selected two
additional functions,
diVidE
and
durArion
, appear in the pulse
output sub-menu.
Using the
&
or
*
push button select
5ourCE
in
the pulse output sub-menu and press
(
. to reveal
the existing pulse source. The function can be
changed by pressing the
&
or
*
push button
followed by the
)
button to return to
5ourCE
prompt.
6.6 Divide output pulse frequency:
diVidE
When the output pulse is derived from the total
display the output pulse frequency may be divided
by:
1
10
100
1000
10000
Using the
&
or
*
push button select
diVidE
in
the pulse output sub-menu and press
(
to reveal
the existing divisor. The value can be changed by
pressing the
&
or
*
push button to select the
required value followed by the
)
button to return
to
diVidE
prompt.
Note:
This function only appears in the sub-menu
when the output pulse is derived from the
total display.
6.7 Output pulse width:
durAtion
When the output pulse is derived from the total
display, the pulse width is defined by this function.
One of 11 pulse widths in milliseconds may be
selected:
0
.
1
0
.
5
1
2
.
5
5
10
25
50
100
250
500
Using the
&
or
*
push button select
durAtion
in
the pulse output sub-menu and press
(
to reveal
the existing pulse duration. The value can be
changed by pressing the
&
or
*
push button to
select the required value followed by the
)
button
to return to
durAtion
prompt.
Note:
This function only appears in the pulse
output sub-menu when the output pulse is
derived from the total display.
24